We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 December 2024
Reseach Article

Mems based Immunosensors for Biodetection and Development of Novel Read-Out Methods

Published on March 2012 by P. Sangeetha, A.Vimala Juliet
2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013)
Foundation of Computer Science USA
NCIPET - Number 2
March 2012
Authors: P. Sangeetha, A.Vimala Juliet
2d9186b3-4178-40fb-9266-01bacaa5d19c

P. Sangeetha, A.Vimala Juliet . Mems based Immunosensors for Biodetection and Development of Novel Read-Out Methods. 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013). NCIPET, 2 (March 2012), 4-8.

@article{
author = { P. Sangeetha, A.Vimala Juliet },
title = { Mems based Immunosensors for Biodetection and Development of Novel Read-Out Methods },
journal = { 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013) },
issue_date = { March 2012 },
volume = { NCIPET },
number = { 2 },
month = { March },
year = { 2012 },
issn = 0975-8887,
pages = { 4-8 },
numpages = 5,
url = { /proceedings/ncipet/number2/5198-1010/ },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Proceeding Article
%1 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013)
%A P. Sangeetha
%A A.Vimala Juliet
%T Mems based Immunosensors for Biodetection and Development of Novel Read-Out Methods
%J 2nd National Conference on Innovative Paradigms in Engineering and Technology (NCIPET 2013)
%@ 0975-8887
%V NCIPET
%N 2
%P 4-8
%D 2012
%I International Journal of Computer Applications
Abstract

Micromechanical cantilevers show great potential as highly sensitive biochemical sensors. Cantilever-based sensing involves the transduction of a biomolecular interaction to a measurable mechanical change in the cantilever resulting from induced surface stresses added mass. In surface stress sensing applications, one side of the cantilever beam is rendered sensitive to a specific target molecule, while the opposing surface is chemically passivated .When target molecules interact with the sensitized surface of the cantilever, the change in surface stress between the sensitized and passivated surfaces results in a measurable mechanical deflection of the cantilever beam.This paper shows micro cantilever based bio detection and different integrated read-out methods and their characterization. We also show that cantilevers have a increased sensitivity by changing their shape and geometry. Recent advances in MEMS promise considerable and realistic potential for the development of innovative and high performance sensing and diagnostic approaches in biomedical field.

References
  1. K. Hansen, et al., “Cantilever-based Optical Deflection Assay for Discrimination of DNA Single Nucleotide Mismatches,” Analytical Chemistry 73, 1567-1571
  2. G. Wu, et al., “Bioassay of Prostate Specific Antigen (PSA) Using Micro cantilevers,” Nature Biotechnology 19, 856-860
  3. Arntz, Y.; Seelig, J.D.; Lang, H.P.; Zhang, J.; Hunziker, P.; Ramseyer, J.P.; Meyer, E.; Hegner, M.; Gerber, C. Label-free protein assay based on a nanomechanical cantilever array. Nanotechnol. 2003.
  4. Nelson, B.P.; Grimsrud, T.E.; Liles, M.R.; Goodman, R.M.; Corn, R.M. Surface Plasmon resonance imaging measurements of DNA microarrays.
  5. Nordstrom, M.; Keller, S.; Lillemose, M.; Johansson, A.; Dohn, S.; Haefliger, D.; Blagoi, G;Havsteen-Jakobsen, M.; Boisen, A. SU-8 cantilevers for bio/chemical sensing; fabrication.characterisation and development of novel read-out methods. Sensors 2008.
  6. He, F. J.; Geng, Q.; Zhu, W.; Nie, L. H.; Yao, S. Z.; Meifeng, C. Rapid detection for E. coli using a separated electrode piezoelectric crystal sensor.
  7. Dhayal, B.; Henne, W. A.; Doorneweerd, D. D.; Reifenberger, R. G.; Low, P. S. Detection of Bacillus subtilis spores using peptide-functionalized cantilever arrays. Journal of the American Chemical Society 2006.
  8. Lavrik, N. V.; Sepaniak, M. J.; Datskos, P. G. Cantilever transducers as a platform for chemical and biological sensors. Review of Scientific Instruments 2004.
  9. Raiteri, R., Grattarola, M., Butt, H.J., Skladal, P., Sensors and Actuators B 79:115-26 (2001)
  10. Hansen, K. M. et al. (2001) Cantilever-based optical deflection assay for discrimination of DNA single-nucleotide mismatches. Anal. Chem. 73: 1567–1571.
  11. Wu, G. et al. (2001) Bioassay of prostate-specific antigen (PSA) using microcantilevers. Nature Biotechnol. 19: 856–860
  12. Su, M., Li, S. & Dravid, V. (2003) Microcantilever resonance-based DNA detection with nanoparticle probes. Appl. Phys. Lett. 82: 3562–62
Index Terms

Computer Science
Information Sciences

Keywords

Mems Based Immunosensors Biodetection Read-Out Methods