We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 December 2024
Reseach Article

Primary Open Angle Glaucoma Diagnosis using Neuro Retinal Rim Ratio

Published on August 2016 by Dnyaneshwari D. Patil, Ramesh R. Manza
National Conference on Digital Image and Signal Processing
Foundation of Computer Science USA
NCDISP2016 - Number 2
August 2016
Authors: Dnyaneshwari D. Patil, Ramesh R. Manza
894a61d1-b777-4158-9a94-aa420164ee68

Dnyaneshwari D. Patil, Ramesh R. Manza . Primary Open Angle Glaucoma Diagnosis using Neuro Retinal Rim Ratio. National Conference on Digital Image and Signal Processing. NCDISP2016, 2 (August 2016), 6-11.

@article{
author = { Dnyaneshwari D. Patil, Ramesh R. Manza },
title = { Primary Open Angle Glaucoma Diagnosis using Neuro Retinal Rim Ratio },
journal = { National Conference on Digital Image and Signal Processing },
issue_date = { August 2016 },
volume = { NCDISP2016 },
number = { 2 },
month = { August },
year = { 2016 },
issn = 0975-8887,
pages = { 6-11 },
numpages = 6,
url = { /proceedings/ncdisp2016/number2/25853-1636/ },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Proceeding Article
%1 National Conference on Digital Image and Signal Processing
%A Dnyaneshwari D. Patil
%A Ramesh R. Manza
%T Primary Open Angle Glaucoma Diagnosis using Neuro Retinal Rim Ratio
%J National Conference on Digital Image and Signal Processing
%@ 0975-8887
%V NCDISP2016
%N 2
%P 6-11
%D 2016
%I International Journal of Computer Applications
Abstract

Glaucoma harms the optic nerve cells that transmit graphic information to the brain. Though IOP is the most considerable reason to extend glaucoma, optic disc parameters are mainly used to find out early stage of glaucoma damage. Glaucoma is nick name as "silent thief of eyesight", as the nickname suggests there are no previous symptoms,but due to this, Glaucoma patient can blind without any previous intimation. For glaucoma diagnosis there are multiplemethods are available like CDR, i. e. optic cup to disc ratio calculation,NRR i. e. Neuro Retinal Rim Ratio. Here we are using NRR to diagnose the glaucoma. For that we use our proposed algorithm on 300 colored retinal fundus images. These are MESSIDORE 100 images, and RIM-One 100 of Glaucomatous and 100 of Normal. Over all we got 68% result from MESSIDORE fundus image dataset. And 100% result from Rim-One normal images and 66% result from Rim-One Glaucomatous dataset.

References
  1. Acharya, U. R. , Ng, E. Y. K. , and Suri, J. S. , "Imagemodeling of humanEye" Artech House, MA, USA, 2008a,April.
  2. U. R. , Chau, K. C. , Ng, E. Y. K. , Wei, W. , and Chee,C. , "Application of higher order spectra for theidentification of diabetes retinopathy stages". J. Medsyst. USA. 2008b. doi: 10. 1007/s10916-008-9154-8.
  3. Song, X. , Chen, Y. , Song, K. , and Chen, Y. , "AComputer – based diagnosis of glaucoma using anartificial neural network". Proceedings of 17th AnnualConference IEEE Engineering in Medicine andBiology, 1, 847-848, 1995. University Science, 1989.
  4. Viranee Thongnuch, Bunyarit Uyyanonvara,"Automatic optic disc detection from low contrastretinal images of ROP infant using mathematicalmorphology", 2000.
  5. Nayak, J. Bhat, P. S. , Acharya, U. R. , Lim, C. M. , and Kagathi, M. ,"Automated identification of different stages of diabetic retinopathy using digital fundusimages". J. Med. Sys. USA. 32:2107-115, 2008,doi:10. 1007/s10917-007-9113-9.
  6. RIM-ONE: An Open Retinal Image Database for Optic Nerve Evaluation F. Fumero, S. Alayon1, J. L. Sanchez, J. Sigut, M. Gonzalez-HernandezDept. of Systems Engineering, University of La Laguna Dept. of Ophthalmology, Hospital Universitario de Canarias
  7. Medha V. Wyawahare1 and Dr. Pradeep M. Patil" Extraction of Optic Cup in Retinal Fundus images: A Compartitive Approach", Vishwakarma Institute of Technology, Bibwewadi, Pune, India 2RMD Sinhgad Technical Institutes' Campus, Warje, Pune, India, International Journal of Signal Processing, Image Processing and Pattern Recognition Vol. 7,No. 2(2014),pp. 389-398 http://dx. doi. org/10. 14257/ijsip. 2014. 7. 2. 36
  8. GangadeviC. Bedke,Dr. RameshR. Manza, Dnyaneshwari D. Patil,Yogesh M. Rajput,"Secondary Glaucoma Diagnosis Technique Using Retinal Nerve Fiber Layer Arteries",Dept. of cs&It Dr. B. A. M. U. Aurangabad,India(ICPC IEEE pune chapter2014).
  9. Manjiri B. Patwari, Ramesh R. Manza, Yogesh M. Rajput,Manoj Saswade,Neha Deshpande,"Automatic Detection of Retinal Venous Beading and Tortuosity by using Image processing Techniques" , International Journal of Computer Applications (0975 – 8887) Recent Advances in Information Technology, 2014.
  10. M. Lakshmi,Glaucoma "Detection from Color Fundus Images Using Multithresholding Method with Median Filter", ISSN 2278 – 0211
  11. Kurnika Choudhary, Shamik Tiwari "ANN Glaucoma Detection using Cup-to-Disk Ratio and Neuroretinal Rim" Mody University of Science and Technology, International Journal of Computer Applications (0975 – 8887) Volume 111 – No 11, February 2015.
  12. Dnyaneshwari D. Patil, Ramesh R. Manza, Gangadevi C. Bedke"Diagnose Glaucoma by Proposed Image Processing Methods"Dept of CS and IT, Dr. B. A. M. University, Aurangabad (MS) (India), International Journal of Computer Applications (0975 – 8887) Volume 106 – No. 8, November 2014
  13. Rim-one dataset available on URL: http://WWW. researchgate. net/publication/224255262_RIMONE_An_open_retinal_image_database_for_optic_nerve_evaluation.
  14. MESSIDORE database URL: http://www. adics. net/en/Download-Third-Party/Messidore. htmlindex-en. php
Index Terms

Computer Science
Information Sciences

Keywords

Cdr (cup To Disc Ratio) Nrr (neuro Retinal Rim) rdr (rim To Disc Ratio) Multithresholding Iop(intra Occular Pressure).