We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 November 2024
Reseach Article

Bioelectrical Impedance: A Future Health Care Technology

Published on January 2014 by Anshul Gupta, Annu Sharma, Padma Batra, Rajiv Kapoor
International IT Summit Confluence 2013-The Next Generation Information Technology Summit
Foundation of Computer Science USA
CONFLUENCE2013 - Number 1
January 2014
Authors: Anshul Gupta, Annu Sharma, Padma Batra, Rajiv Kapoor
fcc02d49-fe94-42fc-a02e-ce192fab8ef4

Anshul Gupta, Annu Sharma, Padma Batra, Rajiv Kapoor . Bioelectrical Impedance: A Future Health Care Technology. International IT Summit Confluence 2013-The Next Generation Information Technology Summit. CONFLUENCE2013, 1 (January 2014), 21-25.

@article{
author = { Anshul Gupta, Annu Sharma, Padma Batra, Rajiv Kapoor },
title = { Bioelectrical Impedance: A Future Health Care Technology },
journal = { International IT Summit Confluence 2013-The Next Generation Information Technology Summit },
issue_date = { January 2014 },
volume = { CONFLUENCE2013 },
number = { 1 },
month = { January },
year = { 2014 },
issn = 0975-8887,
pages = { 21-25 },
numpages = 5,
url = { /proceedings/confluence2013/number1/15114-1305/ },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Proceeding Article
%1 International IT Summit Confluence 2013-The Next Generation Information Technology Summit
%A Anshul Gupta
%A Annu Sharma
%A Padma Batra
%A Rajiv Kapoor
%T Bioelectrical Impedance: A Future Health Care Technology
%J International IT Summit Confluence 2013-The Next Generation Information Technology Summit
%@ 0975-8887
%V CONFLUENCE2013
%N 1
%P 21-25
%D 2014
%I International Journal of Computer Applications
Abstract

Impedance measurement is a fast and cheap method to characterize any matter. Unlike various complicated methods, bioimpedance measurement technique is simple, less time consuming and non-invasive method for various applications including medicine, biotechnology and food industry. However, despite of intensive research in this field of more than six decades, only a few applications have been established. This paper presents a review of the major steps taken towards the development of Bioelectrical Impedance Analysis technique as a future health care technology.

References
  1. Cornish B H, Thomas B J and Ward L C 1993, "Improved Prediction Of Extracellular And Total Body Water Using Impedance Loci Generated By Multiple Frequency Bioelectrical Impedance Analysis" Phys. Med. Biol. 38 337–46
  2. Wikipedia: the free encyclopedia, Bioelectrical Impedance Analysis, 1 MAY 2013, http://en. wikipedia. org/wiki/Bioelectrical_impedance_analysis, 2 JULY 2013
  3. Ursula G. Kylea, Ingvar Bosaeusb, Antonio D. De Lorenzoc, Paul Deurenbergd, Marinos Eliae, Jose Manuel Gomezf, Berit Lilienthal Heitmanng, "Bioelectrical Impedance Analysis Part I: Review Of Principles And Methods" Clinical Nutrition, 2004.
  4. Mart Min, and Toomas Parve, "Improvement of Lock-in Electrical Bio-Impedance Analyzer for Implantable Medical Devices", IEEE Transactions on Instrumentation and Measurement, Vol. 56, NO. 3, JUNE 2007
  5. University Of Vermont, Department of nutrition and food sciences, http://nutrition. uvm. edu/bodycomp/bia/, 3 JULY 2013.
  6. H. P. Schwan, "Electrical Properties of Tissue And Cellsuspensions", Adv Biol Med Phys, vol. 5, pp. 147-209,1957
  7. Ackmann J. J. and SeitzMA 1984, "Methods of Complex Impedance Measurements In Biologic Tissue Crit. Rev. Biomed". Eng. 11 s281–311
  8. Cole K S and Cole R H 1941, "Dispersion and absorption in dielectrics" J. Chem. Phys. 9 341–51
  9. G. Martinsen, J. Nysæther, K. H. Riisnæs, G. Mostad, N. W. Christie, and S. Clausen, "Live Finger Detection by Four-Point Measurement of Complex Impedance", patent application WO2004049942, 2004.
  10. Ørjan G. Martinsen,Sigmund Clausen, Jon B. Nysæther, and Sverre Grimnes, "Utilizing Characteristic Electrical Properties of The Epidermal Skin Layers to Detect Fake Fingers in Biometric Fingerprint Systems—A Pilot Study" IEEE Transactions On Biomedical Engineering, VOL. 54, NO. 5, MAY 2007
  11. Chao Wang, Xiao-li Zhang, Hua-Xiang Wang, "DFT Based Dynamic Multi-Frequency Bioimpedance Detection", Proceedings of the Fifth International Conference on Machine Learning and Cybernetics, Dalian, 13-16 August 2006
  12. Rafael González-Landaeta, Oscar Casas, and Ramon Pallàs-Areny, "Heart Rate Detection From Plantar Bioimpedance Measurements" IEEE Transactions On Biomedical Engineering, vol. 55, no. 3, march 2008 1163
  13. Calin Corciova, Radu Ciorap, Dan Zaharia, Daniela Matei, "Hemodynamic Monitoring Using Peripheral Impedance Plethysmography", The 7th Electrical Symposium On Advanced Topics In Electrical Engineering.
  14. Fernando Seoane Martinez, "Electrical Bioimpedance Cerebral Monitoring: Fundamental Steps towards Clinical Application" PhD thesis, Chalmers University Of Technology Göteborg, Sweden, 2007.
  15. Angelo Rottigni, Marco Carminati, Giorgio Ferrari, Marco Sampietro, "Handheld Bio-Impedance Measurement System Based On An Instrument-On-Chip", Proceedings of IEEE 2011.
  16. Wikipedia: the free encyclopedia, Wien bridge oscillator, 1 May 2013, http://en. wikipedia. org/wiki /Wien_bridge_oscillator, 22 JULY 2013.
Index Terms

Computer Science
Information Sciences

Keywords

Electrical Bio-impedance Multi-frequency Bioimpedance Differential Signal Processing Instrumentation Amplifier