National Conference on Advancements in Alternate Energy Resources for Rural Applications |
Foundation of Computer Science USA |
AERA2015 - Number 3 |
December 2015 |
Authors: Sandeep Kumar, Mahakdeep Singh, Vishal Mahajan |
3d2b51de-6c36-413e-9082-61fb71c7cf53 |
Sandeep Kumar, Mahakdeep Singh, Vishal Mahajan . Working Efficiency Analysis of Working Solar Water Heater with FPC. National Conference on Advancements in Alternate Energy Resources for Rural Applications. AERA2015, 3 (December 2015), 28-32.
To ensure alternative sources of energy that are clean, reliable stable and sustainable solar energy being emerging major need in today era of expensive fuels which is used to boil water for industrial and domestic purpose . An setup of Two moveable solar water heaters with FPC's (flat plate collector solar panel fitted ) of 100 liter and 200 liter were placed in roof top open sky space made available. The data of 12 months have been collected and performance of analyzed in this paper. It is found that the incoming hot tap water is about 30?C higher than the room temperature during day time during winter months. This is about 25?C in afternoon hours.