CFP last date
20 January 2025
Reseach Article

Test Bed Design and Implementation for Biomedical Signal Analysis

by Bhaskar Thakker
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 94 - Number 3
Year of Publication: 2014
Authors: Bhaskar Thakker
10.5120/16323-5580

Bhaskar Thakker . Test Bed Design and Implementation for Biomedical Signal Analysis. International Journal of Computer Applications. 94, 3 ( May 2014), 21-24. DOI=10.5120/16323-5580

@article{ 10.5120/16323-5580,
author = { Bhaskar Thakker },
title = { Test Bed Design and Implementation for Biomedical Signal Analysis },
journal = { International Journal of Computer Applications },
issue_date = { May 2014 },
volume = { 94 },
number = { 3 },
month = { May },
year = { 2014 },
issn = { 0975-8887 },
pages = { 21-24 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume94/number3/16323-5580/ },
doi = { 10.5120/16323-5580 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T22:16:36.761190+05:30
%A Bhaskar Thakker
%T Test Bed Design and Implementation for Biomedical Signal Analysis
%J International Journal of Computer Applications
%@ 0975-8887
%V 94
%N 3
%P 21-24
%D 2014
%I Foundation of Computer Science (FCS), NY, USA
Abstract

This document describes the fundamental requirements of a test bed along with its design and implementation for a biomedical signal acquisition and analysis. A test bed helps in acquiring the signal along with performing signal conditioning for amplification and filtration in simplified manner. Utilization of the Data Acquisition card (DAQ) along with LabView Signal Express software plays an important role in such a design. Such a test bed is designed and successfully tested in this paper for acquiring multi channel wrist pulse pressure signals. The importance of this test bed is concluded at the last. For any kind of long term biomedical signal acquisition, the test bed described here with implementation results gives guidelines for setting up the hardware with minimum efforts and greater accuracies.

References
  1. A. Surve, P. Pandey, S. Pratapwar, V. Pandey, and N. Manigandan, "Enhancement of radial arterial pulse by spectral subtraction," 2004.
  2. "USB6009-Data Acquistion Card, National Instruments" http://sine. ni. com/nips/cds/view/p/lang/en/nid/201987
  3. "INA128 Data Sheet - Texas Instruments" http://www. ti. com/lit/gpn/ina128
  4. "NMK0505SC DC to DC converter" http://www. murataps. com/data/power/ncl/kdc nmk. pdf
  5. "National Instruments Signal Express Software" http://www. ni. com/labview/signalexpress/
  6. H. Rhyner, Ayurveda: the gentle health system, vol. 18. Motilal Banarsidass Publ. ,1998.
  7. S. Upadhyaya, Nadi Vijnana - Ancient Pulse Science. Chaukhamba Sanskrit Pratishthan, 2005.
  8. Bhaskar Thakker and Anoop Lal Vyas "Radial Pulse Analysis at Deep Pressure in Abnormal Health Conditions" IEEE International Conference on Biomedical Engineering and Informatics (BMEI 2010), ISBN: 978-1-4244-6496-8 October 2010 Yentai, China, pp. 1007-1010.
  9. "Pressure Sensor MPXM2053D from Freescale Semiconductor" http://cache. freescale. com/files/sensors/doc/data_sheet/MPX2053. pdf
Index Terms

Computer Science
Information Sciences

Keywords

Test Bed Design Test Bed Implementation Data Acquisition Card (DAQ) LabView Signal Express Pulse pressure sensor