CFP last date
20 January 2025
Reseach Article

Simultaneously Failure of Full Functional Devices and Reduced Functional Devices in Zigbee Sensor Network

by Amritpal Kaur, Jaswinder Kaur, Gurjeevan Singh
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 93 - Number 9
Year of Publication: 2014
Authors: Amritpal Kaur, Jaswinder Kaur, Gurjeevan Singh
10.5120/16246-5803

Amritpal Kaur, Jaswinder Kaur, Gurjeevan Singh . Simultaneously Failure of Full Functional Devices and Reduced Functional Devices in Zigbee Sensor Network. International Journal of Computer Applications. 93, 9 ( May 2014), 42-46. DOI=10.5120/16246-5803

@article{ 10.5120/16246-5803,
author = { Amritpal Kaur, Jaswinder Kaur, Gurjeevan Singh },
title = { Simultaneously Failure of Full Functional Devices and Reduced Functional Devices in Zigbee Sensor Network },
journal = { International Journal of Computer Applications },
issue_date = { May 2014 },
volume = { 93 },
number = { 9 },
month = { May },
year = { 2014 },
issn = { 0975-8887 },
pages = { 42-46 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume93/number9/16246-5803/ },
doi = { 10.5120/16246-5803 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T22:15:23.984579+05:30
%A Amritpal Kaur
%A Jaswinder Kaur
%A Gurjeevan Singh
%T Simultaneously Failure of Full Functional Devices and Reduced Functional Devices in Zigbee Sensor Network
%J International Journal of Computer Applications
%@ 0975-8887
%V 93
%N 9
%P 42-46
%D 2014
%I Foundation of Computer Science (FCS), NY, USA
Abstract

This work is based on the characteristics of IEEE 802. 15. 4 protocol stack. A hybrid topology has been design by using three possible combinations of Zigbee network topologies considered in different scenarios to verify the consistency of this communication network. The scenario has been design under the consideration of device failure in hybrid topologies. There are various parameters like throughput, delay, network load and number hops are measured during these scenarios. The result concludes that Star-Tree hybrid topology is better to make an effective network in case of device malfunctioning. The simulation has been done using OPNET Modeler 14. 5. Simulation results enumerate the affect of Zigbee network hybrid topologies on the basis of performance factors.

References
  1. Karandeep Malhi, Subhas Chandra Mukhopadhyay, MathiasHaefke, and Hartmut Ewald, "A Zigbee - Based Wearable Physiological Parameterz Monitoring System", IEEE sensor journal, vol. 12 NO. 3, march 2012.
  2. Leonardo Goratti, Jussi Haapola, "Highly Reliable Star and Sub-Mesh Hybrid Sensor Network for Smart Grid Monitoring" GC'12 Workshop: Smart Grid Communications: Design for Performance, IEEE GLOBCOM workshop 2012:1480-1485.
  3. Dong Wook Seo, Doo Seop Yun, Sung Ho Cho, "A Network Performance Improvement for One-to-One and Many-to-One Communication Environment in Zigbee" 2007 International Conference on Applied Electronics (CD-ROM), Plzen, Czech Republic, September 5-7, 2007.
  4. Francesca Cuomo, Emanuele Cipollone, Anna Abbagnale"Performance analysis of IEEE 802. 15. 4 wireless sensor networks: An insight into the topology formation process" ELSEVIER, Computer Networks 53 (2009) 3057–3075.
  5. J. Pedro Amaro, Fernando J. T. E. , Ferreira,RuiCortesão, Jorge Landeck, "Powering Wireless Sensor Networks Nodes for Comple Protocols on Harvested Energy", CENTERIS 2012 – Conference on Enterprise Information Systems HCIST 2012 - International Conference on Health and Social Care Technologies, Procedia Technology 5 ( 2012 ) 518 – 526.
  6. Joa-Hyoung Lee, In-Bum Jung, "Speedy Routing Recovery Protocol for Large Failure Tolerance in Wireless Sensor Networks", SENSORS ISSN 1424- 8280.
  7. Mumtaj M. Ali Al-Mukthar, Teeb Hussain Hadi, "Modeling the Performance of Zigbee Cluster Tree Wireless Sensor Network in Presence of Failure", Journal of Advanced Computer Science and Technology Research,Vol. 3 No. 3, September 2013, 116-126.
  8. Macro Gribaudo, Daniele Manini, Alessandro Nordio "trnsient analysis of IEEE 802. 15. 4 sensor network" IEEE Transaction on Wireless communication VOL. 10 No. 4 April 2011.
  9. Jing Sun, Xiaofen Zhang, "Study of ZigBee Wireless Mesh Networks" 2009 Ninth International Conference on Hybrid Intelligent Information Systems and Systems, vol. 02, IEEE Computer Society Washington,DC,USA © 2009 .
  10. Jun Wang, Victor C. M. Leung, "Comparisons of Home Area Network Connection Alternatives for Multifamily Dwelling Units" 2011 4th IFIP International Confrence on New Technologies, Mobility and security NTMS 2011 in paris (france), ©2011 IEEE.
  11. Bogdan Pavkovic, Andrzej Duda, Won-Joo Hwang, Fabrice Theoleyre, "Efficient topology construction for RPL over IEEE 802. 15. 4 in wireless sensor network" ELSEVIER Ad-hoc networks.
Index Terms

Computer Science
Information Sciences

Keywords

Hybrid Network Topology Zigbee Wireless Sensor Network Device Failure.