Performance Evaluation of Various Window Techniques for Noise Cancellation from ECG Signal

by Shivani Sharma, Ravindra Pratap Narwaria
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 93 - Number 19
Year of Publication: 2014
Authors: Shivani Sharma, Ravindra Pratap Narwaria
10.5120/16464-5826

Shivani Sharma, Ravindra Pratap Narwaria . Performance Evaluation of Various Window Techniques for Noise Cancellation from ECG Signal. International Journal of Computer Applications. 93, 19 ( May 2014), 1-5. DOI=10.5120/16464-5826

@article{ 10.5120/16464-5826,
author = { Shivani Sharma, Ravindra Pratap Narwaria },
title = { Performance Evaluation of Various Window Techniques for Noise Cancellation from ECG Signal },
journal = { International Journal of Computer Applications },
issue_date = { May 2014 },
volume = { 93 },
number = { 19 },
month = { May },
year = { 2014 },
issn = { 0975-8887 },
pages = { 1-5 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume93/number19/16464-5826/ },
doi = { 10.5120/16464-5826 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T22:16:07.678506+05:30
%A Shivani Sharma
%A Ravindra Pratap Narwaria
%T Performance Evaluation of Various Window Techniques for Noise Cancellation from ECG Signal
%J International Journal of Computer Applications
%@ 0975-8887
%V 93
%N 19
%P 1-5
%D 2014
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Removal of noise from ECG Signals leads to the accurate analysis of potential diseases. ECG Signals are low frequency signals. In this paper, FIR low pass filter have been designed with the help of window techniques at cut off frequency 60 Hz to remove noise from corrupted signal. Additive white Gaussian noise (AWGN) is added artificially to the ECG samples recorded from MIT-BIH database. Comparison of ECG Signal before and after filtering is done on the basis of two parameters i. e. signal to noise ratio and average power. The results are calculated using Gaussian, Bartlett and Hann window based FIR filter.

References
  1. B. U. Kohler, C. Hennig, and R. Orglmeister , " The principles of software QRS detection" , IEEE Eng. Biomed. Mag. , Vol. no. 21, Issue no. 1, pp. 42-57, 2002.
  2. Sarang L Joshi, Rambabu A Vatti, Rupali V Tornekar, " A Survey on ECG Signal denoising techniques," IEEE-2007; 0-7695-3039-7/07.
  3. Xin Liu, Y. Zheng, M. W. Phyu, Bin Zhao, Minkyu Je, "Multiple Functional ECG Signal is Processing for Wearable Applications of Long Term Cardiac Monitoring," IEEE Transactions on Biomedical Engineering, Vol. 58, No. 2, 2011.
  4. Sara Moein, "FIR Cut off Frequency Calculating for ECG Signal Noise Removing Using Artificial Neural Network," ICSI 2010, Part II, LNCS 6146, pp. 124-131, Springer-Verlag Berlin Heidelberg 2010.
  5. J Jenitta, A. Rajeswari, " Denoising of ECG Signal based on Improved Adaptive filter with EMD and EEMD," Proceedings of 2013 IEEE Conference on Information and Communication Technologies (ICT 2013), 978-1-4673-5758-6/13, IEEE-2013.
  6. Heart-felt Apparel, Available [online]: http://produceconsumerobot. com/heartfeltapparel/.
  7. Bhumika Chandrakar, O. P. Yadav, V. K. Chandra, "A Survey of noise removal Techniques for ECG Signals," International Journal of Advanced Research in Computer and Communication Engineering, Vol. 2, Issue 3, March 2013.
  8. K. D. Chinchkhede, G. S. Yadav, S. R. Hirekhan, D. R. Solanke, "On the Implementation of FIR filter with Various Windows for Enhancement of ECG Signal," International Journal of Engineering Science and Technology , 0975-5462, Vol no. 3, March 2011.
  9. Geeta Kadam, P. C. Bhaskar, "Reduction of Power Line Interference in ECG Signal Using FIR Filter," International Journal of Computational Engineering Research, 2250-3005, Vol. no. 2 , Issue no. 2, Mar-Apr 2012.
  10. C. B. Mbachu, K. J. Offor, "Reduction of Power Line Noise in ECG Signal using FIR Digital Filter Implemented with Hamming Window," International Journal of Science, Environment and Technology, 2278-3687, Vol. no. 2, Issue no. 6, 2013.
  11. Mahesh S. Chavan, R. A. Agarwala, M. D. Uplane, " ,"
  12. Roberts, A. Richard, C. T. Mullis , Digital Signal Processing, Reading, MA: Addison-Wesley, pp. 135-136, 1987.
  13. Oppenheim, V. Alan, Ronald W. Schafer, John R. Buck, "Discrete-Time Signal Processing," Upper Saddle River, NJ: Prentice Hall, pp. 468, 1999.
  14. How to use the PhysioBank ATM, Available [online]: http://physionet. org/cgi-bin/atm/ATM
Index Terms

Computer Science
Information Sciences

Keywords

FIR digital filter Signal to noise ratio (SNR) Average Power Window Technique.