Novel Notch Detection Algorithm for Detection of Dicrotic Notch in PPG Signals

by Sanjeev Nara, Manvinder Kaur, Kundan Lal Verma
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 86 - Number 17
Year of Publication: 2014
Authors: Sanjeev Nara, Manvinder Kaur, Kundan Lal Verma
10.5120/15081-3520

Sanjeev Nara, Manvinder Kaur, Kundan Lal Verma . Novel Notch Detection Algorithm for Detection of Dicrotic Notch in PPG Signals. International Journal of Computer Applications. 86, 17 ( January 2014), 36-39. DOI=10.5120/15081-3520

@article{ 10.5120/15081-3520,
author = { Sanjeev Nara, Manvinder Kaur, Kundan Lal Verma },
title = { Novel Notch Detection Algorithm for Detection of Dicrotic Notch in PPG Signals },
journal = { International Journal of Computer Applications },
issue_date = { January 2014 },
volume = { 86 },
number = { 17 },
month = { January },
year = { 2014 },
issn = { 0975-8887 },
pages = { 36-39 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume86/number17/15081-3520/ },
doi = { 10.5120/15081-3520 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T22:04:45.542137+05:30
%A Sanjeev Nara
%A Manvinder Kaur
%A Kundan Lal Verma
%T Novel Notch Detection Algorithm for Detection of Dicrotic Notch in PPG Signals
%J International Journal of Computer Applications
%@ 0975-8887
%V 86
%N 17
%P 36-39
%D 2014
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Photoplethysmography (PPG) is a non-invasive optical technique that measures relative blood volume changes in the blood vessels and is widely used for research and physiological studies. Dicrotic notch represent the closure of the aortic semi-lunar valve and subsequent receding blood flow when ventricles relax. Their location is used to calculate systolic time intervals and monitor cardiac function. They play a significant role in early evaluation of various diseases such as sclerosis, occlusion, arterial spasm etc. This paper proposes a novel Notch Detection Algorithm (NDA) for detection of dicrotic notches from PPG signal that are measured by non-invasive photoplethysmography sensors. The proposed algorithm is implemented with the help of self developed Graphical User Interface (GUI) in MATLAB.

References
  1. http://jeffreymlevinemd. com/wpcontent/uploads/2010/02/Arterial-Pulsation-Wave-Form_WEB2. jpg
  2. Joydeep Bhattacharya, Partha Pratim Kanjilal and V. Muralidhar, "Analysis and Characterization of Photo-Plethysmographic Signal", IEEE Transaction on Biomedical Engineering, January 2001, Vol. 48, No. 1, pp 5-23.
  3. K. L. Verma, A. K. Jaiswal and S. S. Chandel, "Statistical Methods of Bio-Physiological Data Processing," ISBN 978-3-659-31141-3, Lambert Academic Publishing, Germany, 2012
  4. K. Meigas, R. Kattai and M. Nigul, "Comparisons of Signal of Pulse Profile as Skin Surface Vibration PPG and Doppler Spectrogram for Continuous Blood Pressure Monitoring," Proceeding of the International Federation for Medical and Biological Engineering, 2002, Vol. 3, pp. 510-511.
  5. L. Antonelli, W. Ohley and R. Khamlach, "Dicrotic notch detection using wavelet transform analysis," IEEE, 1994, pp. 1216-1217.
  6. M. H. Sherebin, R. Z. Sherebin, "Frequency Analysis of Peripheral Pulse Wave Detected in the Finger with Photoplethysmograph," IEEE Transaction on Biomedical Engineering, March 1999, Vol. 37, No. 3.
  7. M. J. Oppenheim and D. F. Sittig, "An Innovative Dicrotic Notch Detection Algorithm which combines Rule-based logic with Digital Signal Processing Techniques," Computers and Biomedical Research, 1995, pp. 154-170
  8. Prakhar Prakash, Meghna Sareen, Rohin Anand, Abhinav and Sneh Anand, "Application of wavelets based multiresolution analysis to detect relevant points of interest from finger-tip photoplethesmography and pressure signal from the radial artery," Proceedings of the IEEE : CIBEC'08, 2008
  9. R. B. Blažek , Chien-Cheng Lee, "Multi-resolution Linear Model Comparison for Detection of Dicrotic Notch and Peak in Blood Volume Pulse Signals," Analysis of Biomedical Signals and Images; 2010, 20: 378-386
  10. Sangeeta Bagha and Laxmi Shaw, "Real Time Analysis of PPG Signal for Measurement of SpO2 and Pulse Rate," International Journal of Computer Applications, December 2011, Vol. 36– No. 11, pp. 45-50
  11. Subhash Bharati, Girmallappa Gidveer, "Waveform Analysis of Pulse Wave Detected in the fingertip with PPG" International Journal of Advances in Engineering & Technology, March 2012, Vol. 3, pp. 92-100
  12. Swarup Sarkar, Akash Kumar Bhoi and Gyanesh Savita , "Fingertip Pulse Wave (PPG signal) Analysis and Heart Rate Detection," International Journal of Emerging Technology and Advanced Engineering, September 2012, Volume 2, pp. 404-408
Index Terms

Computer Science
Information Sciences

Keywords

Photoplethysmography Dicrotic Notch Notch Detection Algorithm Graphical User Interface