CFP last date
20 January 2025
Reseach Article

Deblurring and Denoising of Magnetic Resonance Images using Blind Deconvolution Method

by Arunabha Debnath, Hari Mohan Rai, Chahat Yadav, Anjali Agarwal, Ankit Bhatia
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 81 - Number 10
Year of Publication: 2013
Authors: Arunabha Debnath, Hari Mohan Rai, Chahat Yadav, Anjali Agarwal, Ankit Bhatia
10.5120/14046-2209

Arunabha Debnath, Hari Mohan Rai, Chahat Yadav, Anjali Agarwal, Ankit Bhatia . Deblurring and Denoising of Magnetic Resonance Images using Blind Deconvolution Method. International Journal of Computer Applications. 81, 10 ( November 2013), 7-12. DOI=10.5120/14046-2209

@article{ 10.5120/14046-2209,
author = { Arunabha Debnath, Hari Mohan Rai, Chahat Yadav, Anjali Agarwal, Ankit Bhatia },
title = { Deblurring and Denoising of Magnetic Resonance Images using Blind Deconvolution Method },
journal = { International Journal of Computer Applications },
issue_date = { November 2013 },
volume = { 81 },
number = { 10 },
month = { November },
year = { 2013 },
issn = { 0975-8887 },
pages = { 7-12 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume81/number10/14046-2209/ },
doi = { 10.5120/14046-2209 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T21:55:41.928412+05:30
%A Arunabha Debnath
%A Hari Mohan Rai
%A Chahat Yadav
%A Anjali Agarwal
%A Ankit Bhatia
%T Deblurring and Denoising of Magnetic Resonance Images using Blind Deconvolution Method
%J International Journal of Computer Applications
%@ 0975-8887
%V 81
%N 10
%P 7-12
%D 2013
%I Foundation of Computer Science (FCS), NY, USA
Abstract

This paper describes the methods to improve the quality of blurred and noisy Magnetic Resonance Images (MRI) due to motion artifact. The main objective of this work is to restore original image from a motion-blurred image due to defocused optical system and motion artifact which is a challenging problem in digital imaging. The blind deconvolution method has been applied to restore the clear image from the blurred and noisy MRI images in this paper. There exist several techniques to restore the original image corrupted by various noise and blurred due to motion artifact, but these methods lack to fetch the originality of image. Blind deconvolution is a method to recover the sharp version of a blurred image when the source of blurring is not known. The aim of this paper is to analyze and evaluate recent blind deconvolution algorithms both theoretically and experimentally for deblurring and noise removal of MRI mges. The MRI data used was corrupted by Gaussian noise and blurred due to various cause (gaussian blurring, out-of-focus blur and motion blur etc). The comparisons of the techniques were done on the basis of Peak signal to noise ratio (PSNR) and Mean structural similarity index (MSSIM). The proposed technique proved to be better over methods used for deblurring and denoising of MRI images.

References
  1. Zheng Lou, "Blind Deconvolution for Image Restoration Using Recursice Filtering" pp. 2-11, April-2005.
  2. NRC. Mathematics and Physics of Emerging Biomedical Imaging. National Research Council, Institute of Medicine, National Academy Press, Washington DC, 1996. http://www. nas. edu/.
  3. M. Mignotte, J. Meunier, J. P. Soucy, and C. Janicki, "Comparison of deconvolution techniques using a distribution parameter estimation: Application in single positron emission computed tomography imagery", Journal of Electronic Imaging, vol. 11, pp. 5–14, 2002.
  4. B. Bascle, A. Blake, and A. Zisserman. Motion deblurring and super-resolution from an image sequence. In ECCV, pages 573–582, 1996.
  5. M. Ben-Ezra and S. K. Nayar. Motion-based motion deblur- ring. IEEE Trans. PAMI, 26(6):689–698, 2004.
  6. Y. Lu, J. Sun, L. Quan, and H. Shum. Blurred/non-blurred image alignment using an image sequence. In SIGGRAPH, 2007.
  7. R. Raskar, A. Agrawal, and J. Tumblin. Coded exposure photography: Motion deblurring via ?uttered shutter. In SIG- GRAPH, volume 25, pages 795–804, 2006.
  8. J. Chen, L. Yuan, C. K. Tang, and L. Quan. Robust dual motion deblurring. In CVPR, 2008.
  9. Y. Tai, H. Du, M. S. Brown, and S. Lin. Image/video deblur- ring using a hybrid camera. In CVPR, 2008.
  10. G. A. Wright, "Magnetic Resonance Imaging", IEEE Signal Processing Magazine, vol. 1, pp. 56-66, (1997).
  11. H. C. Andrews and B. R. Hunt. Digital Image Restauration. PRENTICE-HALL SIGNAL PROCESSINH SERIES. PRENTICE-HALL, INC. , Englewood Cli?s, New Jersey, 1977.
Index Terms

Computer Science
Information Sciences

Keywords