We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 December 2024
Reseach Article

Measuring Blood Glucose Levels with Microwave Sensor

by Shiv Kumar, Jaspal Singh
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 72 - Number 15
Year of Publication: 2013
Authors: Shiv Kumar, Jaspal Singh
10.5120/12568-8911

Shiv Kumar, Jaspal Singh . Measuring Blood Glucose Levels with Microwave Sensor. International Journal of Computer Applications. 72, 15 ( June 2013), 4-9. DOI=10.5120/12568-8911

@article{ 10.5120/12568-8911,
author = { Shiv Kumar, Jaspal Singh },
title = { Measuring Blood Glucose Levels with Microwave Sensor },
journal = { International Journal of Computer Applications },
issue_date = { June 2013 },
volume = { 72 },
number = { 15 },
month = { June },
year = { 2013 },
issn = { 0975-8887 },
pages = { 4-9 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume72/number15/12568-8911/ },
doi = { 10.5120/12568-8911 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T21:37:58.828318+05:30
%A Shiv Kumar
%A Jaspal Singh
%T Measuring Blood Glucose Levels with Microwave Sensor
%J International Journal of Computer Applications
%@ 0975-8887
%V 72
%N 15
%P 4-9
%D 2013
%I Foundation of Computer Science (FCS), NY, USA
Abstract

In this paper an effort is made to documentation of the design of microwave sensor which can be used for non –invasive blood glucose monitoring . It is very simple and cost effective self monitoring continuous blood2 glucose monitoring system . The software used for microwave sensor was Sonnet Lite Project Editor V-13. 55® which was freely available on the internet. Two oscillators were used 500-2000 Mhz frequency due to design limitation of sensor. Simulation result shows where there was a change in blood glucose level there will also change in the body impedance. With using multimeter value could easily be measure. Purposed hardware and result also shown in this paper.

References
  1. Y. Nikawa and D. Someya,2001 "Non-invasive measurement of blood sugar level by millimeter waves"
  2. E. C. Green, 2004. "Proposed Method for Non-Invasive Measurement of Blood Glucose Concentration: Using Microwaves for Data Measurement and Analysis"
  3. Gabriel, R. W. Lau and C. Gabriel, 2005 "The Dielectric Properties of Biological Tissues"
  4. Y. Nikawa and D. Someya, 2005"Non-invasive measurement of blood sugar level by millimeter waves"
  5. A. Caduff, E. Hirt, Y. Feldman, Z. Ali and L. Heinemann,2005 "First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system"
  6. J. H. Park, C. S. Kim, B. C. Choi and K. Y. Ham,2006" The correlation of the complex dielectric constant and blood glucose at low frequency, Biosensors and Bioelectronics"
  7. W. Davis, 2007 "IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3 kHz to 300 GHz"
  8. A. Rosen, M. A. Stuchly and A. V. Vorst, 2008 "Applications of RF/microwaves in medicine,"
  9. J. P. Grant, R. N. Clarke, G. T. Symm and N. M. Spyrou, 2009"In vivo dielectric properties of human skin from 50 MHz to 2. 0 GHz,".
  10. R. Pethig,2010 "Dielectric properties of body tissues"
Index Terms

Computer Science
Information Sciences

Keywords

Microwave sensor Diabetes Non-invasive Impedance Glucose measurement