We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 November 2024
Reseach Article

Voltage Collapse Avoidance by using STATCOM

by Champa Nandi, Jhuma Rudra Pal, Tandra Sutradhar
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 70 - Number 12
Year of Publication: 2013
Authors: Champa Nandi, Jhuma Rudra Pal, Tandra Sutradhar
10.5120/12017-8079

Champa Nandi, Jhuma Rudra Pal, Tandra Sutradhar . Voltage Collapse Avoidance by using STATCOM. International Journal of Computer Applications. 70, 12 ( May 2013), 36-42. DOI=10.5120/12017-8079

@article{ 10.5120/12017-8079,
author = { Champa Nandi, Jhuma Rudra Pal, Tandra Sutradhar },
title = { Voltage Collapse Avoidance by using STATCOM },
journal = { International Journal of Computer Applications },
issue_date = { May 2013 },
volume = { 70 },
number = { 12 },
month = { May },
year = { 2013 },
issn = { 0975-8887 },
pages = { 36-42 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume70/number12/12017-8079/ },
doi = { 10.5120/12017-8079 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T21:32:42.738245+05:30
%A Champa Nandi
%A Jhuma Rudra Pal
%A Tandra Sutradhar
%T Voltage Collapse Avoidance by using STATCOM
%J International Journal of Computer Applications
%@ 0975-8887
%V 70
%N 12
%P 36-42
%D 2013
%I Foundation of Computer Science (FCS), NY, USA
Abstract

This paper deals with modelling and simulation of STATCOM in IEEE 14 bus System with Induction Motor load for avoiding voltage collapse. Three Phases to ground fault is applied in predominant Induction motor load bus for voltage collapse analysis. The effect of Critical Fault Clearing Time [CFCT] of the system due to facing the fault, to prevent permanent voltage collapse has been analyzed with and without STATCOM. Simulations of the STATCOM were carried out by using Power System Computer Aided Design (PSCAD) software. Simulation results prove that the STATCOM is capable of mitigating voltage collapse with minimum clearing Time.

References
  1. Abu-Siada, Chatura Karunar, "Improvement Of Transmission Line Power Transfer Capability, Case Study", Electrical and Electronics Engineering: An International Journal (EEEIJ) Vol. 1, No. 1, May 2012.
  2. Hendri Masdi, Norman Mariun, S. M. Bashi, Azah Mohamed, Sallehhudin Yusuf," Construction of a Prototype D-Statcom for Voltage Sag Mitigation "European Journal of Scientific Research ,ISSN 1450-216X Vol. 30 No. 1 (2009), pp. 112-127
  3. S. HADJERI, Fatiha GHEZAL ,S. A. ZIDI, " Simulation of a three level 48 pulses Statcom " 2008-Mediamira science Publisher. Volume 49, Number 2, 2008.
  4. S. H. Hosseini, R. Rahnavard, Y. Ebrahimi, "Reactive Power Compensation in Distribution Networks with STATCOM by Fuzzy logic Theory Application",5th International Power Electronics and Motion Control Conference (IPEMC), Shanghai, China, 14-16August 2006 (CD).
  5. S. H. Hosseini, R. Rahnavard, "Comparison of Two Methods for Shunt Active Power Filter under the Distorted Source Voltages Condition" ,ECTI-CON, Rachthani, Thailand, pp. 9-13, Rachthani, 10-13 May 2006.
  6. S. Sundeep, Dr. G. Madhusudhana Rao," Modelling and Analysis of Custom Power Devices for Improve Power Quality", International Journal of Electrical and Computer Engineering (IJECE),Vol. 1, No. 1, September 2011, pp. 43~48, ISSN: 2088-8708.
  7. Facts Modelling and Simulation in Power Networks. By. Enrique Acha,Claudio R. Fuerte-Esquivel,Hugo Ambriz-Perez,Cesar Angeles-Camacho,(p. 17,p. 155-178).
Index Terms

Computer Science
Information Sciences

Keywords

STATCOM Reactive power compensation Voltage Collapse CFCT Stability