CFP last date
20 January 2025
Reseach Article

Specialized Finite Element Analysis Computer Software for Modeling Hemodynamics in Abdominal Aortic and Carotid Artery Bifurcation Aneurysms

by Vijayajothi Paramasivam, Kanesan Muthusamy, Nenad Filipovic
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 65 - Number 19
Year of Publication: 2013
Authors: Vijayajothi Paramasivam, Kanesan Muthusamy, Nenad Filipovic
10.5120/11033-5648

Vijayajothi Paramasivam, Kanesan Muthusamy, Nenad Filipovic . Specialized Finite Element Analysis Computer Software for Modeling Hemodynamics in Abdominal Aortic and Carotid Artery Bifurcation Aneurysms. International Journal of Computer Applications. 65, 19 ( March 2013), 25-32. DOI=10.5120/11033-5648

@article{ 10.5120/11033-5648,
author = { Vijayajothi Paramasivam, Kanesan Muthusamy, Nenad Filipovic },
title = { Specialized Finite Element Analysis Computer Software for Modeling Hemodynamics in Abdominal Aortic and Carotid Artery Bifurcation Aneurysms },
journal = { International Journal of Computer Applications },
issue_date = { March 2013 },
volume = { 65 },
number = { 19 },
month = { March },
year = { 2013 },
issn = { 0975-8887 },
pages = { 25-32 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume65/number19/11033-5648/ },
doi = { 10.5120/11033-5648 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T21:19:16.892629+05:30
%A Vijayajothi Paramasivam
%A Kanesan Muthusamy
%A Nenad Filipovic
%T Specialized Finite Element Analysis Computer Software for Modeling Hemodynamics in Abdominal Aortic and Carotid Artery Bifurcation Aneurysms
%J International Journal of Computer Applications
%@ 0975-8887
%V 65
%N 19
%P 25-32
%D 2013
%I Foundation of Computer Science (FCS), NY, USA
Abstract

The developed computer software system is particularly suitable for three dimensional investigations of hemodynamic conditions in abdominal aortic and carotid artery bifurcation aneurysms. It consists of two major clinically relevant modeling scope; rigid wall and deformable wall models. It provides an integrated set of tools that help solve clinically relevant hemodynamic variables such as velocity, wall shear stress and pressure profiles that aids in predicting disease development. The developed graphical user interface is essential for creating mathematical models of an aneurysm with prescribed boundary and initial conditions. This user-friendly interface automatically performs geometric model constructions, input data preparations, model discretizations, computational modeling and post-processing options of the aneurismal models. The blood flow dynamics is defined according to the incompressible Navier-Stokes and the continuity equations for viscous fluids. The computational modeling technique is based on finite element method. Because of the increasing size and complexity of the analysis and the software system design to date, a change in the programming approach and a shift in software design strategy have been proposed for developing readable, expandable and maintainable software systems. This change is from the procedure-oriented to object-oriented programming system development methodologies.

References
  1. Cotran, R. S. , Kumar. V. and Robbins, S. L. 1994 Robbins pathologic basis of decease. Chapter 11, 499-504, Saunders, London.
  2. Newman, A. B. , Arnold, A. M. , Burke, G. L. , O'Leary, D. H. , and Manolio, T. A. 2001 Cardiovascular disease and mortality in older adults with small abdominal aortic aneurysms detected by ultrasonography: the cardiovascular health study. Annals of Internal Medicine, 134, 182-190.
  3. Clement Kleinstreuer, and Zhonghua Li. 2006 Analysis and computer program for rupture-risk prediction of abdominal aortic aneurysm. BioMedical Engineering OnLine, 5:19.
  4. Myers, K. , Devine, T. , Barras, C. and Self G. 2001 Endoluminal versus open repair for abdominal aortic aneurysms. http://www. fac. org. ar/scvc//llave/interven/myers/myersi. htm.
  5. Limet, R. , Sakalihassan, N. , and Albert, A. 1991 Determination of the expansion rate and incidence of rupture of abdominal aortic aneurysms. Journal of Vascular Surgery, 14, 540-548.
  6. Fillinger, M. F. , Raghavan, M. L. , Marra, P. , Cronenwett, L. and Kennedy E. 2002 In vivo analysis of mechanical wall stress and abdominal aortic aneurysm rupture risk. Journal of Vascular Surgery, 36, 589-596.
  7. Fillinger, M. F. , Raghavan, M. L. , Marra, P. S. and Kennedy, E. F. 2003 Prediction of rupture in abdominal aortic aneurysm during observation: wall stress vs diameter. Journal of Vascular Surgery, 37, 724-732.
  8. Strandness, D. E. , and Eikelboom, B. C. 1998 Carotid artery stenosis-where do we go from here? European J. Ultrasound, 7, 17-26.
  9. Ku, D. N. 1997 Blood flow in arteries, Annu. Rev. Fluid Mech. 29, 399-434.
  10. Perktold, K. , Resch, M. , and Peter, R. O. 1991 Three-dimensional numerical analysis of pulsatile flow and wall shear stress in the carotid artery bifurcation model, J. Biomechanics, 24, 409-420.
  11. Cokelet, G. 1987 The rheology and tube flow of blood. In: Skalak R. & Chen S. , (eds. ) Handbook of Bioengineering, New York: McGraw-Hill.
  12. Sadeghipour, M. and Hajari B. 1995 The pulsatile blood-flow in deformable vessels – non Newtonian behavior. In: Hochmuth R. , Langrana N. , Hefy M. , (Eds) Proceedings of 1995 Bioengineering Conference, BED, 29, ASME.
  13. Quarteroni, A. , Tuveri, M. , and Veneziani, A. 2000 Computational vascular fluid dynamics: problems, models and methods. Comp. Visual Sci. , 2, 163-197.
  14. Cho, Y. J. , and Kensey, K. R. 1991 Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel. Part 1: Steady flow. Biorheology, 28, 241-262.
  15. Peattie, R. A. , Riehle, T. J. , and Bluth, E. I. 2005 Pulsatile flow in fusiform models of abdominal aortic aneurysms: flow fields, velocity patterns and flow-induced wall stresses, J. Biomech. Eng. , 126, 438-446.
  16. Christine M. Scotti, Alexander D. Shkolnik, Satish C. Muluk, and Ender A. Finol 2006 Fluid-structure interaction in abdominal aortic aneurysms: effects of asymmetry and wall thickness, BioMedical Engineering OnLine, 4:64.
  17. Perktold, K. , and Rappitsch, G. 1995 Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model, J. Biomechanics, 28, 845-856.
  18. Filipovic, N. , and Kojic, M. 2004 Computer simulation of blood flow with mass transport through the carotid artery bifurcation. Theoret. Appl. Mech. 31 (1), 1-33.
  19. Kojic, M. , Filipovic, N. , Zivkovic, M. , Slakovic, R. and Grujovic, N. 1999 PAK-F finite element program for laminar flow of incompressible fluid and heat transfer. Laboratory of Engineering Software, Faculty of Mechanical Engineering, University of Kragujevac.
  20. Kojic, M. , Filipovic, N. , Zivkovic, M. , Slavkovic, R. , and Grujovic, N. 1998 PAK-FS Finite Element Program for Fluid-Structure Interaction. Faculty of Mech. Engrg, University of Kragujevac, (1998), Serbia.
Index Terms

Computer Science
Information Sciences

Keywords

Computer software object-oriented programming three dimensional finite element analysis hemodynamic abdominal aortic aneurysm carotid artery bifurcation aneurysm