CFP last date
20 January 2025
Reseach Article

Automatic Segmentation of Connected Thin Peripheral Vessels in Chest CT Scan Images

by P. Ammi Reddy, E. V. Krishna Rao, I. Ramesh Babu
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 54 - Number 9
Year of Publication: 2012
Authors: P. Ammi Reddy, E. V. Krishna Rao, I. Ramesh Babu
10.5120/8594-2353

P. Ammi Reddy, E. V. Krishna Rao, I. Ramesh Babu . Automatic Segmentation of Connected Thin Peripheral Vessels in Chest CT Scan Images. International Journal of Computer Applications. 54, 9 ( September 2012), 17-24. DOI=10.5120/8594-2353

@article{ 10.5120/8594-2353,
author = { P. Ammi Reddy, E. V. Krishna Rao, I. Ramesh Babu },
title = { Automatic Segmentation of Connected Thin Peripheral Vessels in Chest CT Scan Images },
journal = { International Journal of Computer Applications },
issue_date = { September 2012 },
volume = { 54 },
number = { 9 },
month = { September },
year = { 2012 },
issn = { 0975-8887 },
pages = { 17-24 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume54/number9/8594-2353/ },
doi = { 10.5120/8594-2353 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T20:55:15.383717+05:30
%A P. Ammi Reddy
%A E. V. Krishna Rao
%A I. Ramesh Babu
%T Automatic Segmentation of Connected Thin Peripheral Vessels in Chest CT Scan Images
%J International Journal of Computer Applications
%@ 0975-8887
%V 54
%N 9
%P 17-24
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Vessel enhancement and segmentation is one of the crucial pre-processing steps in accurate vessel tree reconstruction in many chest CT scan imaging applications. Conservative vessel enhancement approaches used eigenvalues of Hessian-based filters, which are found to be sensitive to noise, fails to detect small ones, and sometimes give discontinued vessels due to junction suppression. Since Hessian-based filters cannot distinguish step edges from vessels effectively, in this paper, we propose a novel framework to overcome the problems for vessel enhancement for thorax CT images. The road map of proposed work has three steps. First, extract the lung region from thorax CT images based on Gray-level thresholding and morphological operations; then, according to the idea of the matched filter in different directions, and local entropy thresholding, to obtain more precise analysis in noisy environment and thus can correctly reveal entire vessels. Also, qualitative as well as quantitative evaluations performed on CT images show that the proposed filter generates better performance in comparison against two Hessian-based approaches (Frangi and Shikata). .

References
  1. E Li, S. Sone, H. Abe, H. MacMahon, S. Aimato Ill, and K. Doi. "Lung cancers missed at low-dose helical CT screening in a general population: comparison of clinical, histopathologic, and imaging findings," Radiology, vol. 225, pp. 673-683, 2002.
  2. W. Huang, R. Yen, M. McLaurine, and G. Bledsoe, "Morphometry of the human pulmonary vasculature," Journal of Applied Physiology, vol. 81, pp. 2123-2133, 1996.
  3. Hidenoris hikata,Geoffrey McLennan, Eric A. Hoffman, and Milan Sonka, "Segmentation of Pulmonary Vascular Trees from Thoracic 3D CT Images", in Hindawi Publishing Corporation International Journal of Biomedical Imaging Volume 2009, Article ID636240, 11 pages doi:10. 1155/2009/636240.
  4. O. Agam, S. O. Armato III. and C. Vu, "Vessel tree reconstruction in thoracic CT scans with application to nodule detection," IEEE Trans. Med. Imaging, vol. 24, no. 4, pp. 486-499, 2005.
  5. A. F. Frangi, W. J. Niessen, K. L. Vincken, and M. A. Viergever, "Multiscale vessel enhancement filtering," in Medical Inage computing and Computer Assisted Intervention, 1998, pp. 130-137.
  6. Panayiotis D. Kor?atis, Cristina Kalogeropoulou, Anna N. Karahaliou, Alexandra D. Kazantzi, and Lena I. Costaridou, "Vessel Tree Segmentationin Presence of Interstitial Lung Disease in MDCT" , in IEEE Transactionson Information Technology in Biomedicine, vol. 15, no. 2, pp. 214-220, March 2011.
  7. Y. Sato, S. Nakajima, N. Shigara, H. Atsumi, T. Koller, G. Gerig, and R. Kikinis, "Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images," Med. Img. Analysis, vol. 2, no. 2, pp. 143-168, 1998.
  8. Q. Li, S. Sone, arid K. Doi, "Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans," Medical Physics, vol. 30, no. 8, pp. 2040-2051, 2003.
  9. L. Cohcn and T. Dcschamps, "Segmentation of 3D tubular objects with adaptive front propagation and minimal tree extraction for 3D medical imaging," Computational Methods in Biomechanics and Biomedical Engineering, vol. 10, no. 4, pp. 289-305, 2007.
  10. G. Song, A. Ramirez-Manzanares, and J. Gee, "A simultaneous segmentation and regularization framework for vessel extraction in CT images," in First international workshop on pulmonary image processing, pp. 185-193, 2008.
  11. Panayiotis D. Kor?atis, Anna N. Karahaliou, Alexandra D. Kazantzi, Cristina Kalogeropoulou, and Lena I. Costaridou, "Texture Based Identi?cation and Characterization of Interstitial Pneumonia Patterns in Lung Multidetector CT" in IEEE Transactionson Information Technology in Biomedicine, vol. 14, no. 3, pp. 675-680, May 2010.
  12. Yanfeng Shang, Rudi Deklerck, Edgard Nyssen, Aneta Markova, Johande Mey, Xin Yang, and Kun Sun, "Vascular Active Contourfor Vessel Tree Segmentation", IEEE Transactions on Biomedical Engineering, vol. 58,no. 4, pp. 1023-1032, April 2011.
  13. N. Otsu, "A threshold selection method from gray-level histograms," IEEE Transactions on Systems,Man, and Cybernetics, vol. SMC-9, pp. 62-66, Jan. 1979.
  14. S. Chaudhuri, S. Chatterjee, N. Katz, M. Nelson, and M. Goldbaum, "Detection of blood vessels in retinal images using two dimensional matched filters," IEEE Trans. Medical imaging, vol. 8, no. 3,pp. 263-269, September 1989.
  15. Chang, C. -I. ; Du, Y. ; Wang, J. ; Guo, S. -M. ; Thouin, P. D. , Survey and comparative analysis of entropy and relative entropy thresholding techniques, Vision, Image and Signal Processing, Page(s):837 – 850, IEE Proceedings, Vol. 153, 2006.
  16. M. Dolejsi, J. Kybic, M. Polovincak, and S. Tuma, "The Lung TIME-Annotated lung nodule dataset and nodule detection framework," in Proceedings of SPIE, Vol. 7260, 72601U, 2009.
  17. T. Fawcett, ROC Graphs: Notes and Practical Considerations for Researchers, Technical Report, HP Laboratories, Palo Alto, USA, 2004.
Index Terms

Computer Science
Information Sciences

Keywords

Vessel enhancement Hessian-based matched ?lter computer aided detection