An Implementation of Different Non Linear PID Controllers on a single Tank level Control using Matlab

by D. V. L. N. Sastry, Gssssv.krsihna Mohan, M. S. R. Naidu, N. Mohana Rao
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 54 - Number 1
Year of Publication: 2012
Authors: D. V. L. N. Sastry, Gssssv.krsihna Mohan, M. S. R. Naidu, N. Mohana Rao
10.5120/8528-2060

D. V. L. N. Sastry, Gssssv.krsihna Mohan, M. S. R. Naidu, N. Mohana Rao . An Implementation of Different Non Linear PID Controllers on a single Tank level Control using Matlab. International Journal of Computer Applications. 54, 1 ( September 2012), 6-8. DOI=10.5120/8528-2060

@article{ 10.5120/8528-2060,
author = { D. V. L. N. Sastry, Gssssv.krsihna Mohan, M. S. R. Naidu, N. Mohana Rao },
title = { An Implementation of Different Non Linear PID Controllers on a single Tank level Control using Matlab },
journal = { International Journal of Computer Applications },
issue_date = { September 2012 },
volume = { 54 },
number = { 1 },
month = { September },
year = { 2012 },
issn = { 0975-8887 },
pages = { 6-8 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume54/number1/8528-2060/ },
doi = { 10.5120/8528-2060 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T20:54:34.640692+05:30
%A D. V. L. N. Sastry
%A Gssssv.krsihna Mohan
%A M. S. R. Naidu
%A N. Mohana Rao
%T An Implementation of Different Non Linear PID Controllers on a single Tank level Control using Matlab
%J International Journal of Computer Applications
%@ 0975-8887
%V 54
%N 1
%P 6-8
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

A Single tank level control system has one rectangular tank which has inflow of liquid into the tank and out flow through valve. The control System is intended to maintain the level of liquid in the tank at some predefined value irrespective of changes inflow of tank. Conventional PID controller gives better results due to changes in load. Thus change in inflow or changes in predefined values are treated as disturbances to the process. According to these disturbances we need to implement better tuning algorithms to PID controllers. But industrial conventional PID controllers exhibits nonlinear output for the given error values. Thus the approach of non linear PID controller is to include the disturbance parameters to conventional PID controller. The behavior is observed with step input. In this paper we implemented different non linear PID control algorithms on tank level control System and their responses are observed.

References
  1. Chemical process control-An Introduction to theory and Practice by George Stephanopoulos, Pearson Prentice Hall – ISBN 81-7758-403-0.
  2. Process Systems Analysis and Control by Donald R. Coughanowr-Second edition –McGRAW-HILL International editions
  3. An Application of Nonlinear PID Control by Fangjun Jiang
  4. Special non linear PID controllers-www. protuner. com
  5. Non linear Digital PID controller by Shamim choudhury Texas Instruments .
  6. Process control instrumentation by –c. d. Jhonson
  7. Ziegler, J. G. and N. B. , Nichols, "Optimal settings for automatic controllers", Trans. ASME, Vol. 64, pp. 759-768 (1942).
  8. Cohen, G. H. and G. A. , Coon, "Theoretical consideration of retarded control", Trans. ASME, Vol. 75, pp. 827-834 (1953).
  9. Smith, C. A. and C. B. , Corripio, Principals andPractices of Automatic Control, Wiley, New York,(1985).
Index Terms

Computer Science
Information Sciences

Keywords

Single Tank control Non linear PID MATLAB tool