We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 November 2024
Reseach Article

ZigBee based Patient Monitoring System

by Jaikaran Singh, Mukesh Tiwari, Manisha Shelar
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 51 - Number 22
Year of Publication: 2012
Authors: Jaikaran Singh, Mukesh Tiwari, Manisha Shelar
10.5120/8342-1761

Jaikaran Singh, Mukesh Tiwari, Manisha Shelar . ZigBee based Patient Monitoring System. International Journal of Computer Applications. 51, 22 ( August 2012), 17-20. DOI=10.5120/8342-1761

@article{ 10.5120/8342-1761,
author = { Jaikaran Singh, Mukesh Tiwari, Manisha Shelar },
title = { ZigBee based Patient Monitoring System },
journal = { International Journal of Computer Applications },
issue_date = { August 2012 },
volume = { 51 },
number = { 22 },
month = { August },
year = { 2012 },
issn = { 0975-8887 },
pages = { 17-20 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume51/number22/8342-1761/ },
doi = { 10.5120/8342-1761 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T20:51:00.969291+05:30
%A Jaikaran Singh
%A Mukesh Tiwari
%A Manisha Shelar
%T ZigBee based Patient Monitoring System
%J International Journal of Computer Applications
%@ 0975-8887
%V 51
%N 22
%P 17-20
%D 2012
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Statistics reveal that every minute a human is losing his/her life across the globe. More close in India , everyday many lives are affected by heart attacks and more importantly because the patients did not get timely and proper help . There are many emergency response services striving hard to save the lives of people during emergencies, though they are successful at few times. But sometimes they fail to race against time to reach the victim. All over the globe , emergency response service is the need of the hour.

References
  1. Ovidiu Apostu, Bogdan Hagiu, Sever Pa?ca, "Wireless ECG Monitoring and Alarm System Using ZigBee"2011 The International Symposium on ADVANCED TOPIC INELECTRICAL ENGINEERING2068-7966/ATEE 2011.
  2. Arun Kumar, Fazlur Rahman, "Wireless Health Alert and Monitoring System", 81-904262-1-4/06/ c_ 2006 Research Publishing Services.
  3. Muhammad Ali Mazidi, Janice Gillispie Mazidi, 8051 Microcontroller and Embedded Systems, Prentice-Hall, Page:183-193, 236, 243.
  4. Dogan Ibrahim, Microcontroller Projects in C for the 8051, Newnes, Page:29-161.
  5. Kenneth J. Ayala, The 8051 Microcontroller ARCHITECTURE, PROGRAMMING and APPLICATIONS, WEST PUBLISHING COMPANY, Page:131-197.
  6. Ramakant A. Gayakwad, Op-Amps and Linear Integrated Circuits, 4th Edition, Prentice-Hall, Page:342, 417, 455.
  7. R. P. Jain, Digital Electronics, Tata McGraw-Hill www. electronic-circuits-diagrams. com
Index Terms

Computer Science
Information Sciences

Keywords

ZigBee Patient Monitoring System