CFP last date
20 January 2025
Reseach Article

SMS based Load Shedding Period Control System

by Dwijen Rudrapal, Smita Das, Swapan Debbarma, Goutam Pal
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 29 - Number 7
Year of Publication: 2011
Authors: Dwijen Rudrapal, Smita Das, Swapan Debbarma, Goutam Pal
10.5120/3579-4954

Dwijen Rudrapal, Smita Das, Swapan Debbarma, Goutam Pal . SMS based Load Shedding Period Control System. International Journal of Computer Applications. 29, 7 ( September 2011), 8-14. DOI=10.5120/3579-4954

@article{ 10.5120/3579-4954,
author = { Dwijen Rudrapal, Smita Das, Swapan Debbarma, Goutam Pal },
title = { SMS based Load Shedding Period Control System },
journal = { International Journal of Computer Applications },
issue_date = { September 2011 },
volume = { 29 },
number = { 7 },
month = { September },
year = { 2011 },
issn = { 0975-8887 },
pages = { 8-14 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume29/number7/3579-4954/ },
doi = { 10.5120/3579-4954 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T20:15:43.443701+05:30
%A Dwijen Rudrapal
%A Smita Das
%A Swapan Debbarma
%A Goutam Pal
%T SMS based Load Shedding Period Control System
%J International Journal of Computer Applications
%@ 0975-8887
%V 29
%N 7
%P 8-14
%D 2011
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Energy is one of the basic requirements in modern civilization, without which various indispensable applications will bind to bring to a standstill. It is really not possible to measure the actual enormity of the function that energy has accomplished in connection with human advancement. As energy plays such a significant role in our day-to-day life, hence we should confer a precedence to accumulate it by the use of load shedding. Conventional methods of load shedding systems are too slow to calculate efficiently the accurate amount of load to be shed. This consequences either excessive or insufficient load reduction. In latest years, load shedding systems have been carried out using conventional under-frequency relay and/or breaker interlocks schemes incorporated with Programmable Logic Controllers to give an innovative glance to an obsolete load preservation methodology. In true sense, period of load shedding can be controlled with a computerized power management system where rapid and optimal load management can be done. Again, the Computerized Load Shedding Control System can now be extended and it can be controlled by a SMS based system. This paper demonstrates the need for a modern load shedding scheme and introduces the idea of developing a SMS based procedure for controlling the load-shedding system where manual work will be minimized by selecting the feeder, substation and duration of shedding time by the user by sending SMS. Simulation results’, using the above proposed model, verifies the suitability of choosing such a SMS based automated load shedding period control system.

References
  1. C. Concordia, L.H. Fink, and Geroge Poullikkas, “Load shedding on an isolated system,” IEEE Trans. Power Syst., vol. 10, pp. 1467-1472, Aug. 1995.
  2. D. Guilfoyle, E. Connolly, “Distributed SCADA systems for electricity distribution control,” Power Technology Int., pp. 169-172, 1994.
  3. C.Bouchoucha, N.mansouri, M.Annabi. Adaptation of the production to the consumption of the electric power and design of the adjustment in the grid systems. GEI2002, March 2002
  4. High Fidelity Simulation Power System Dynamics; J.F. Vernotte, P. Panciatici, B. Meyer, J.P. Antoine, J. Deuse and M. Stubbe; (IEEE Computer Applications in Power, 1995).
  5. D. Rudrapal et. al. “Automated Load Shedding Period Control Systems”, International Journal on Computer Sc. & Engineering, Vol 3, Issue 5, pp. 1159 - 1168, May 2011.
  6. Mukhopadhyay T. and Bhattacharyya B. “Congestion in SMS-Based Query-Response Mechanism – A Possible Solution”, in International Conference on Advances in Computing, Control & Telecommunc. Technologies, December 2009.
  7. J.J. Ford, H. Bevrani, G. Ledwich, "Adaptive load shedding and regional protection", International Journal of Electrical Power & Energy Systems, Volume 31, Issue 10, November-December 2009, Pages 611- 618.
  8. http://faculty.kfupm.edu.sa/EE/mderiche/downloads/farooq.pdf
  9. www2.selinc.com/techpprs/6339_AppRedundLoadShed_NS_20080929.pdf
  10. Tom Wilson, PLC Based Substation Automation and SCADA Systems; Selecting a Control System Integrator, Western Electric Power Institute, March 1999.
  11. S. J. Huang, and C. -C. Huang, “An adaptive load shedding method with time-based design for isolated power systems,” International Journal of Electrical Power & Energy Systems, vol. 22, no. 1, January 2000, pp. 51-58.
  12. Yamamoto, R., Hideyuki, M., Hideo, M., Tomoyoshi, O. & Hiroyuki, O., “Position Location Technologies Using Signal Strength in Cellular Systems”, Vehicular Technology Conference VTC 2001, Spring IEEE, VTS, 4 (53), PP. 2570-4, November 2001
  13. Copeland J. “The Turing Test”, Minds and Machines, Pg. 519-539.
  14. Wave-com Built-in GSM/GPRS modem,User Manual, 2001.
  15. Wavecom AT Commands Interface Guide, 2001, Version 001/9, November.
  16. Micrologic ML-250 handheld GPS receiver operator’s Manual, 1996. May.
  17. T. Leibfried, “Online monitor keeps transformer in service,” in IEEE Computer Applications in Power, vol. 11, July 1998, pp.36-42.
Index Terms

Computer Science
Information Sciences

Keywords

Load Shedding Energy Electricity SMS Based System Substation Feeder Shedding Time