We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 December 2024
Reseach Article

Simulation of Electric Energy Consumption Monitoring System Air Conditioning Equipment

by Ali A. S. Ramschie, Johan F. Makal, Veny V. Ponggawa
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 182 - Number 17
Year of Publication: 2018
Authors: Ali A. S. Ramschie, Johan F. Makal, Veny V. Ponggawa
10.5120/ijca2018917865

Ali A. S. Ramschie, Johan F. Makal, Veny V. Ponggawa . Simulation of Electric Energy Consumption Monitoring System Air Conditioning Equipment. International Journal of Computer Applications. 182, 17 ( Sep 2018), 19-24. DOI=10.5120/ijca2018917865

@article{ 10.5120/ijca2018917865,
author = { Ali A. S. Ramschie, Johan F. Makal, Veny V. Ponggawa },
title = { Simulation of Electric Energy Consumption Monitoring System Air Conditioning Equipment },
journal = { International Journal of Computer Applications },
issue_date = { Sep 2018 },
volume = { 182 },
number = { 17 },
month = { Sep },
year = { 2018 },
issn = { 0975-8887 },
pages = { 19-24 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume182/number17/29954-2018917865/ },
doi = { 10.5120/ijca2018917865 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-07T01:11:41.543411+05:30
%A Ali A. S. Ramschie
%A Johan F. Makal
%A Veny V. Ponggawa
%T Simulation of Electric Energy Consumption Monitoring System Air Conditioning Equipment
%J International Journal of Computer Applications
%@ 0975-8887
%V 182
%N 17
%P 19-24
%D 2018
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Using of air conditioning equipment to cool the room, has become one of the needs especially in areas with hot climates. In operation, users do not know how much electricity consumption is consumed by air conditioning equipment, so that it can potentially cause electricity waste. This research aims to make a system simulation through proteus simulation program, which can monitor electrical energy consumption from air conditioning equipment, through input data from the current sensor that is processed by the controller, then informed through the LCD display as information on the amount of electrical energy consumption from air conditioning equipment. From the test results, it was found that, systems that are made can monitor the amount of electrical energy consumption from air conditioning equipment, where the monitoring results are displayed through the LCD display. The information displayed is the amount of electricity consumption in watt hour (Wh) and the amount of the price paid in rupiah (Rp).

References
  1. Buntarto, “Service dan Reparasi AC”, Graha Ilmu, Yogyakarta, 2009
  2. Handoko J, “Merawat dan Memperbaiki AC”, Kawan Pustaka, Jakarta, 2009.
  3. A. G. Smith, “Introduction To Arduino”, 2011.
  4. Sujadi, “Teori dan Aplikasi Mikrokontroler”, Cetakan Pertama, Graha Ilmu, Yogyakarta, 2005.base Web Server”, Electrical and Power Engineering (EPE), International Conference and Expocition on, 2014.
  5. Allegro mikrosistem.inc. “Datasheet ACS712”.
  6. Husnawati, Rossi Passarella, Sutarno dan Rendyansyah, “Perancangan dan Simulasi Energi Meter Digital Satu Phasa Menggunakan Sensor Arus ACS712”, JNTETI Vol. 2. No. 4, November 2013.
  7. Ilham, Amil Ahmad, and Ali Ramschie. "SISTEM MONITORING DAN KENDALI KERJA AIR CONDITIONING BERBASIS MIKROKONTROLLER ATmega 8535.", Jurnal Ristek Vol.2, No.1, Juni 2013.
  8. A. A. S. Ramschie, J. F. Makal, V. V. Ponggawa, “Method of Freon Leak Detection and Dirty Air Filter in Air Conditioning for Electrical Savings”, International Journal of Computer Applications, Vol. 172 No.1, 2017.
  9. Ali A.S. Ramschie, Johan Makal, Veny Ponggawa, “Algorithms Air Conditioning Air Filter Detection System For Electric Energy Savings”, International Journal of Computer Application (IJCA), Vol. 156 No. 8, 2016.
  10. M. Mossolly, K. Ghali, N. Ghaddar, “Optimal Control Strategy For a Multy-Zone Air Conditioning System Using The Genetic Algorithm”, ELSEVIER Vol. 34, Issue 1, page 58-66, 2009.
  11. Chiou. C.B., Chu C.M. dan Lin, S.L. “The study of energisaving strategy for direct expansion air conditioning system”Energi and Buildings 40. 1660–1665,2008.
  12. Widell. K.N. dan Eikevik. T. “Reducing power consumption in multi -compressor refrigeration sistems” International Journal of Refrigeration 33. 88-94,2009.
  13. Zhou, Y.P., Wu, J.Y., Wang, R.Z. & Shiochi, S.“Energi simulation in the variable refrigerant flow air-conditioning sistem under cooling conditions” Energi and Buildings 39. 212–220, 2007.
Index Terms

Computer Science
Information Sciences

Keywords

Simulation Proteus Controller Electrical Energy Air Conditioning.