CFP last date
20 January 2025
Reseach Article

European Extremely Large Telescope: Cross-calibration of DIMM Monitors at Aklim Site

by M. Sabil, Z. Benkhaldoun, A. Habib
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 174 - Number 6
Year of Publication: 2017
Authors: M. Sabil, Z. Benkhaldoun, A. Habib
10.5120/ijca2017915412

M. Sabil, Z. Benkhaldoun, A. Habib . European Extremely Large Telescope: Cross-calibration of DIMM Monitors at Aklim Site. International Journal of Computer Applications. 174, 6 ( Sep 2017), 1-4. DOI=10.5120/ijca2017915412

@article{ 10.5120/ijca2017915412,
author = { M. Sabil, Z. Benkhaldoun, A. Habib },
title = { European Extremely Large Telescope: Cross-calibration of DIMM Monitors at Aklim Site },
journal = { International Journal of Computer Applications },
issue_date = { Sep 2017 },
volume = { 174 },
number = { 6 },
month = { Sep },
year = { 2017 },
issn = { 0975-8887 },
pages = { 1-4 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume174/number6/28408-2017915412/ },
doi = { 10.5120/ijca2017915412 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-07T00:21:24.315262+05:30
%A M. Sabil
%A Z. Benkhaldoun
%A A. Habib
%T European Extremely Large Telescope: Cross-calibration of DIMM Monitors at Aklim Site
%J International Journal of Computer Applications
%@ 0975-8887
%V 174
%N 6
%P 1-4
%D 2017
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Differential Image Motion Monitor (DIMM) is the standard instrument for site testing, it has become the instrument of choice to measure the seeing and it is now regularly used in many observatories. Since the DIMM instruments are not identical, a cross-calibration is necessary before making a reliable comparison between any two sites using this instrument. The differences are generally due to the instrumental configuration and data processing. in order to carry out a prospecting campaign at Aklim site in Moroccan Anti-Atlas; it’s one site from four selected sites to harbor the European Extremely Large Telescope (E-ELT) project. To begin a preliminary survey campaign of measurements, a local DIMM instrument a local DIM instrument has been built, and to characterize this instrument, we have carried out a crosscalibration campaign between this local DIMM named LPHEADIMM (DIMM of Laboratory Physics of High Energy and Astrophysics) with a stable existing DIMM, hereafter IAC-DIMM (DIMM of Instituto de Astrof´isica de Canarias). In this paper we represent the results of the 11 nights cross-calibration at Aklim site.

References
  1. Pedersen, H., Rigaut, F., Sarazin, M.: Seeing measurements with a differential image motion Monitor. Messenger, 1988, 53, 89.
  2. Vernin, J., Mu˜noz-Tu˜n´on, C.: Measuring astronomical seeing: the DA/IAC DIMM, 1995, PASP 107, 265272
  3. Ehgamberdiev, S.A., Baijumanov, A.K., Ilyasov, S.P., Sarazin, M., Tillayev, Y.A., Tokovinin, A.A., Ziad, A.: The astroclimate of Maidanak Observatory in Uzbekistan. A and A Suppl. Ser. 2000, 145, 293304
  4. N´u˜nez, J.M., Bohigas, J., Lazo, F., Hiriart, D., Calvario,T., Escoboza, O., Guill´en, F.P.: Intercalibration of the San Pedro M´artir and CTIO DIMM units. Rev. Mex. Astron. Astrofis. 2007, 43, 283290
  5. Giovanelli, R., Darling, J., Sarazin, M. et al. The optical/ infrared astronomical quality of high Atacama sites. I. Preliminary results of optical seeing. PASP, 2001, 113, 789802
  6. Hach, Y., Abahamid, A., Sabil, M., Benhida, A., Benkhaldoun, Z., Habib, A. and Elazhari, Y: Cross-calibration of DIMM monitors at Oukaimden observatory and Marrakesh site, Exp Astron, 2010, 28:8799 DOI 10.1007/s10686-010-9192-3
  7. Martin, H. M. Image motion as a measure of seeing quality. 1987, PASP, 99, 1360
  8. Sarazin, M. and Roddier, F.The ESO differential image motion monitor. 1990, A and A, 227, 294
  9. Tokovinin, A. From Differential Image Motion to Seeing. 2002, PASP, 114, 1156
  10. Benkhaldoun, Z., Abahamid, A., El Azhari, Y. and Lazrek, M. Optical seeing monitoring at the Ouka¨imeden in the Moroccan high atlas mountains: first statistics. 2005, A and A, 441, 839
  11. Sarazin, M. and Roddier, F.The ESO differential image motion monitor. 1990, A and A, 227, 294
  12. Munoz-Tunon, C., Vernin, J., and Varela, A. M. Night-time image quality at Roque de LOS Muchachos Observatory. 1997, A and A, S, 125, 183 Murdin, P. 1985, Vistas Astron., 28, 449
  13. Sabil, M., Benkhaldoun, Z., Lazrek, M., Benhida, A., Hach, Y., Habib, A. and Bounhir, A., First characterization of Jbel Aklim in Moroccan Anti-Atlas as a potential site for the E-ELT. Meteorological parameters and seeing measurements, 2010, A and A, 69, 522
  14. Vernin, J., et al. European Extremely Large Telescope Site Characterization I: Overview, 2011, PASP, 123, 1334.
Index Terms

Computer Science
Information Sciences

Keywords

DIMM Data analysis Cross-calibration