CFP last date
20 December 2024
Reseach Article

Laser Doppler Flow Meter: A New Approach for Calculation of Human Blood Flow Rate

by Nikhil A. Shinde, K. Sujatha, Ashlesha Kulkarni
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 127 - Number 17
Year of Publication: 2015
Authors: Nikhil A. Shinde, K. Sujatha, Ashlesha Kulkarni
10.5120/ijca2015906721

Nikhil A. Shinde, K. Sujatha, Ashlesha Kulkarni . Laser Doppler Flow Meter: A New Approach for Calculation of Human Blood Flow Rate. International Journal of Computer Applications. 127, 17 ( October 2015), 35-38. DOI=10.5120/ijca2015906721

@article{ 10.5120/ijca2015906721,
author = { Nikhil A. Shinde, K. Sujatha, Ashlesha Kulkarni },
title = { Laser Doppler Flow Meter: A New Approach for Calculation of Human Blood Flow Rate },
journal = { International Journal of Computer Applications },
issue_date = { October 2015 },
volume = { 127 },
number = { 17 },
month = { October },
year = { 2015 },
issn = { 0975-8887 },
pages = { 35-38 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume127/number17/22824-2015906721/ },
doi = { 10.5120/ijca2015906721 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T23:18:18.522860+05:30
%A Nikhil A. Shinde
%A K. Sujatha
%A Ashlesha Kulkarni
%T Laser Doppler Flow Meter: A New Approach for Calculation of Human Blood Flow Rate
%J International Journal of Computer Applications
%@ 0975-8887
%V 127
%N 17
%P 35-38
%D 2015
%I Foundation of Computer Science (FCS), NY, USA
Abstract

In this paper, we are going to introduce the new technique for measurement of blood flow rate in humans based on LDF (Laser Doppler Flowmetry) technique. We had developed overall embedded system which takes input from laser Doppler blood flow sensor & gives output on personal computer via wireless communication. The structure of the sensor consists of two compartments with a light dependant resistor (LDR) and a laser diode in each. The size & weight of sensor & overall system is very less. The overall system is powered through a dedicated battery & hence power saving arrangement is also provided. Proper blood flow in human body is essential because an adequate amount of blood supply is necessary for the proper functioning of all body organs as blood carries all the nutrients and oxygen that our body needs to stay healthy. Improper blood flow rate is main symptoms of various diseases. The measurement of the blood flow can therefore provide essential information for the judgment of diseases. Since changes in blood flow occurs with the very primary stage of disease, with a fast, reliable blood flow measurement technique, the physicians have a new option for early disease diagnosis. So using this system, we can successfully & easily able to measure human blood flow rate. Major advantage of this technique is this method is non-invasive which means not involving the introduction of instruments into the body[1][2]

References
  1. Kei Nishihara, Wataru Iwasaki, Masaki Nakamura, Eiji Higurashi, Member, IEEE, Tomoki Soh, Toshihiro Itoh, Hironao Okada, Ryutaro Maeda, and Renshi Sawada “Development of a Wireless Sensor for the Measurement of Chicken Blood Flow Using the Laser Doppler Blood Flow Meter Technique” in IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, VOL. 60, NO. 6, JUNE 2013
  2. G. Lopez, M. Shuzo, and I. Yamada, “New healthcare society supported by wearable sensors and information mappling based services,” Int. J. Netw. Virtual Org., vol. 9, pp. 233–247, 2011
  3. Y. Kimura, A. Onoe, E. Higurashi, and R. Sawada, “Low-power consumption integrated laser Doppler blood flowmeter with a built-in silicon microlens,” in Proc. Int. Conf. Opt. MEMS Nanophoton., Freiburg, Germany, Aug. 2010, pp. 13–14.
  4. Y. Kimura, M. Goma, A. Onoe, E. Higurashi, and R. Sawada, “Integrated laser Doppler blood flowmeter designed to enable wafar-level packaging,” IEEE Trans. Biomed. Eng., vol. 57, no. 8, pp. 2026–2033, 2008
  5. K. Itao, “Wearable sensor network connecting artifacts, nature and human being,” in Proc. IEEE Sensors Conf.,Atlanta, USA, 2007, pp. 1120–1123.
  6. A. Lymberis, “Advanced wearable health systems and applications—Research and development efforts in the European union,” IEEE Eng. Med. Biol. Mag., vol. 26, no. 3, pp. 29–33, May/Jun. 2007.
  7. R. Bonner and R. Nossal, “Model for laser Doppler measurements of blood flow in tissue,” Appl. Opt., vol. 20, pp. 2097–2107, 1981.
  8. Doi, A. Iwasawa, T. Nakamura, and Y. Tanabe, “Plasma melatoninrhythm of the human,” Anim. Sci. Technol., vol. 66, pp. 16–26, May 2006
  9. A. N. Serov, J.Nieland, S. Oosterbaan, F. F.M. deMul,H. van Kranenburg H. H. P. Th. Bekman, and W. Steenbergen, “Integrated optoelectronic probe including a vertical cavity surface emitting laser for laser Doppler perfusion monitorin,” IEEE Trans. Biomed. Eng., vol. 53, no. 10, pp. 2067– 2074, Oct. 2006.
  10. E.Higurashi,R. Sawada, and T. Ito, “An integrated laser blood flowmeter,”J. Lightw. Technol., vol. 21, pp. 591–595, 2003.
Index Terms

Computer Science
Information Sciences

Keywords

blood flow laser Doppler flowmetry low power consumption LDF Sensor wireless non-invasive