We apologize for a recent technical issue with our email system, which temporarily affected account activations. Accounts have now been activated. Authors may proceed with paper submissions. PhDFocusTM
CFP last date
20 December 2024
Reseach Article

Wireless Reliable Embedded System for Patient Monitoring

by Neeta Desai, Saniya Ansari
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 113 - Number 17
Year of Publication: 2015
Authors: Neeta Desai, Saniya Ansari
10.5120/19921-2088

Neeta Desai, Saniya Ansari . Wireless Reliable Embedded System for Patient Monitoring. International Journal of Computer Applications. 113, 17 ( March 2015), 35-38. DOI=10.5120/19921-2088

@article{ 10.5120/19921-2088,
author = { Neeta Desai, Saniya Ansari },
title = { Wireless Reliable Embedded System for Patient Monitoring },
journal = { International Journal of Computer Applications },
issue_date = { March 2015 },
volume = { 113 },
number = { 17 },
month = { March },
year = { 2015 },
issn = { 0975-8887 },
pages = { 35-38 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume113/number17/19921-2088/ },
doi = { 10.5120/19921-2088 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T22:51:12.947393+05:30
%A Neeta Desai
%A Saniya Ansari
%T Wireless Reliable Embedded System for Patient Monitoring
%J International Journal of Computer Applications
%@ 0975-8887
%V 113
%N 17
%P 35-38
%D 2015
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Care of critically ill patient requires prompt & accurate decisions so that we can protect as well as save the life. Due to such requirements, ICUs have become widely established in hospitals. In most hospitals difficulty is that expert has to regularly visit the patient & asses his/her condition by measuring different parameters. These systems works when there is any emergency by using different wireless technologies. This paper is mainly based on continuous monitoring aspect of home patients. This requires a reliable, energy efficient patient monitoring system that can be able to send parameters of patient in real time. So the doctors can monitor patients parameters easily(temp, Pulse rate ,Blood Glucose). The major goal of the final proposed system is that it detects processes and sends patients data (temp, Pulse rate, Blood Glucose)over a wireless.

References
  1. Rajashri Patil, Prof. Balaji Hogade," On Line Real Time Health Monitoring of ICU Patients using ARM7", (IJCSN), Volume-1, Issue-3, 2012.
  2. Dogan Ibrahim, Kadri Buruncuk "HEART RATE MEASUREMENT FROM THE FINGER USING A LOW-COST MICROCONTROLLER",2006.
  3. Takur Chetan Singh,K. S. R. Murty," Wirelss Sensor Networks for Monitoring Physiological Signals of Multiple Patients", IJSR,India Online, ISSN: 2319-7064, Volume 2, Issue-9, September 2013.
  4. N. Beaulah , AL. Kumarappan, "HOME BASED WELLNESS MONITORING SYSTEM THROUGH MEMS TECHNOLOGY", (IJCSE), Vol. 4 No. 3 Jun-Jul 2013
  5. MS. Shilpa W. Bali, Prof V. M. Rohokale, Prof. V. V. Deotare "Performance of Wireless Biomedical Signals Transmitter By Using ARM-7 IJET Volume 3 Issue5-2012.
  6. G. Virone, N. Noury, and J. Demongeot,"A system for automatic measurement of circadian activity deviations in telemedicine,"IEEE Trans. Biomed. Eng. vol. 49, no. 12, pp. 1463-1469, Dec. 2002.
  7. Ananthanarayanan. V,Mithun Haridas TP,Rajeswari A, "Reliable and Affordable Embedded System Solution for Continious Blood Glucose Maintaing System with Wireless Connectivity to Blood Glucose Measuring System",IJCA,2013
  8. B. Sirisha1, T. Sraddha2, K. Vijayanand,"Real-Time Multi-Patient Monitoring System Using ARM and Wireless Sensor Network ", ISSN:2231-1882,Volume-2,Issue-2,2013
  9. AL. Kumarappan Home Based Welleness Monitoring System Through MEMS Technology,ISSN : 0976-5166 Vol. 4 No. 3 Jun-Jul 2013
  10. Chris A. Otto, Emil Jovanov, and Aleksandar Milenkovic,
  11. A WBAN-based System for Health Monitoring at Home, 3rd IEEE/EMBS International Summer School On Medical Devices and BioSensors - ISSMDBS, 2006, pp 20-23
  12. Christian Bachmann, Maryam Ashouei, Valer Pop, Maja Vidojkovic, Harmke de Groot, and Bert Gyselinckx, Low-Power Wireless Sensor Nodes for Ubiquitous Long-Term Biomedical Signal Monitoring, IEEE Communications Magazine, January 2012
  13. Ahmed N. Abdalla, Muhammad Nubli, Tan Chien Siong, Fauzan Khairi, A. Noraziah, Enhancement of real-time multi-patient monitoring system based on wireless sensor networks, International Journal of Physical Sciences, vol. 6, no. 4, February, 2011
  14. DONG Jun, ZHANG Jia-wei1, ZHU Hong-hai1, WANG Li-ping, LIU Xia, LI Zhen-jiang, Wearable ECG Monitors and Its Remote Diagnosis Service Platform, IEEE Intelligent Systems, 2011
  15. Xin Liu, Yuanjin Zheng, Myint Wai Phyu, F. N. Endru, V. Navaneethan, and Bin Zhao, An Ultra-Low Power ECG Acquisition and Monitoring ASIC System for WBAN Applications, IEEE Journal on Emerging and Selected Topics in Circuits and Systems, vol. 2, no. 1, March 2012
  16. R. Suji Pramila,Shajin Nargunam,A Survey on Effective in-Home Health Monitoring System. In IJCA,volume 68-No. 7,April 2013.
  17. P. S. Pandian, K. P. Safeer, P. Gupta, D. T. Shakunthala, B. S. Sundersheshu and V. C. Padaki, Wireless Sensor Network for Wearable PhysMonitoring,
  18. Freescale Application Note: AN4025 - Implementing a Glucometer and Blood Pressure Monitor Medical Devices by Carlos Casillas and Roxana Suarez
  19. www. datasheetcatalog. com/datasheets. . . /-/LCD-016Moo2B
  20. www. datasheetdir. com/LM35+Temperature-Sensors
  21. www. dataheetcatalog. com/datasheet/M/MAX232. shtm
Index Terms

Computer Science
Information Sciences

Keywords

Blood Glucose Real time wireless technology Glucometer Syringe pump.