International Journal of Computer Applications |
Foundation of Computer Science (FCS), NY, USA |
Volume 104 - Number 1 |
Year of Publication: 2014 |
Authors: Sonali Baweja, Ashish Kumar |
10.5120/18164-9024 |
Sonali Baweja, Ashish Kumar . Reliability Measures of a Two-Unit Cold Standby Repairable System with Priority to Operation over Preventive Maintenance. International Journal of Computer Applications. 104, 1 ( October 2014), 5-9. DOI=10.5120/18164-9024
The main objective of present work is to carry out various important reliability measures of a two-unit cold standby repairable system with priority to operation over preventive maintenance by using regenerative points technique and semi-Markov process. A single repair facility is provided to conduct repair and maintenance of the system as and when required. All times distributions are exponential except the repair and preventive maintenance time distributions which are considered as general.