CFP last date
20 December 2024
Reseach Article

A Grey Level Fitting Mechanism based on Gompertz Function for Two Phase Flow Imaging using Electrical Capacitance Tomography Measurement Systems

by Josiah Nombo, Alfred Mwambela, Michael Kisangiri
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 101 - Number 8
Year of Publication: 2014
Authors: Josiah Nombo, Alfred Mwambela, Michael Kisangiri
10.5120/17705-8704

Josiah Nombo, Alfred Mwambela, Michael Kisangiri . A Grey Level Fitting Mechanism based on Gompertz Function for Two Phase Flow Imaging using Electrical Capacitance Tomography Measurement Systems. International Journal of Computer Applications. 101, 8 ( September 2014), 7-12. DOI=10.5120/17705-8704

@article{ 10.5120/17705-8704,
author = { Josiah Nombo, Alfred Mwambela, Michael Kisangiri },
title = { A Grey Level Fitting Mechanism based on Gompertz Function for Two Phase Flow Imaging using Electrical Capacitance Tomography Measurement Systems },
journal = { International Journal of Computer Applications },
issue_date = { September 2014 },
volume = { 101 },
number = { 8 },
month = { September },
year = { 2014 },
issn = { 0975-8887 },
pages = { 7-12 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume101/number8/17705-8704/ },
doi = { 10.5120/17705-8704 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T22:31:07.313775+05:30
%A Josiah Nombo
%A Alfred Mwambela
%A Michael Kisangiri
%T A Grey Level Fitting Mechanism based on Gompertz Function for Two Phase Flow Imaging using Electrical Capacitance Tomography Measurement Systems
%J International Journal of Computer Applications
%@ 0975-8887
%V 101
%N 8
%P 7-12
%D 2014
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Electrical Capacitance Tomography (ECT) is an image generating system based on soft field sensory system. The preferred Linear Back Projection (LPB) reconstruction algorithm for multi-phase measurement has blurring effect on the image generated. These two inherent factors, among others, affect the quality of image generated from ECT systems. Introducing fitting in the image generation process is one the solutions to improving its quality. In this article an alternative fitting mechanism based on the Gompertz function has been developed and evaluated. Comparative analysis results shows improvement on the spatial quality of images generated, in terms of minimum relative image and distribution errors, maximum correlation coefficient, and at relatively no additional computational cost. The mechanism is more effective for annular than stratified flow data hence complimenting the weakness of Xie method for annular flow.

References
  1. Mwambela A J and Johansen G A 2001 Multiphase flow component volume fraction measurement: experimental evaluation of entropic thresholding methods using an electrical capacitance tomography system Meas. Sci. Technol. 12 1092–101
  2. Dyakowski T, Jeanmeure L and Jaworski A 2000 Applications of electrical tomography for gas–solids and liquid–solids flows—a review Powder Technol.
  3. PTL 2014 Industries & Applications of Process Tomography
  4. ITS 2014 Applications of Process Tomography
  5. Xie C G, Plaskowski A and Beck M S 1989 8-electrode capacitance system for two-component flow identification. Part 1: Tomographic flow imaging IEE Proc. A (Physical Sci. Meas. Instrumentation, Manag. Educ. 136 173–83
  6. Huang S M, Plaskowski A B, Xie C G and Beck M S 1989 Tomographic imaging of two-component flow using capacitance sensors J. Phys. E. 22 173–7
  7. Xie C G, Huang S M, Beck M S, Hoyle B S, Thorn R, Lenn C and Snowden D 1992 Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors IEE Proc. G (Circuits, Devices Syst. 139 89–98
  8. Mwambela A, Isaksen Ø and Johansen G 1997 The use of entropic thresholding methods in reconstruction of capacitance tomography data Chem. Eng. Sci.
  9. Peng L, Ye J, Lu G and Yang W 2012 Evaluation of effect of number of electrodes in ECT sensors on image quality Sensors Journal, IEEE 12 1554–65
  10. Aster R C, Borchers B and Thurber C H 2013 Parameter estimation and inverse problems (Academic Press)
  11. Kirsch A 2011 An introduction to the mathematical theory of inverse problems vol 120 (Springer)
  12. Bilionis I and Zabaras N 2014 Solution of inverse problems with limited forward solver evaluations: a Bayesian perspective Inverse Probl. 30 15004
  13. Isaksen Ø and Nordtvedt J E 1994 An implicit model based reconstruction algorithm for use with a capacitance tomography system Proc. European Concerted Action on Process Tomography, Oporto pp 215–26
  14. Isaksen Ø 1996 A review of reconstruction techniques for capacitance tomography Meas. Sci. Technol. 7 325
  15. Jang J D, Lee S H, Kim K Y and Choi B Y 2006 Modified iterative Landweber method in electrical capacitance tomography Meas. Sci. Technol. 17 1909
  16. Jinchuang Z, Wenli F, Taoshen L and Shi W 2002 An image reconstruction algorithm based on a revised regularization method for electrical capacitance tomography Meas. Sci. Technol. 13 638
  17. Jing L, Liu S, Zhihong L and Meng S 2009 An image reconstruction algorithm based on the extended Tikhonov regularization method for electrical capacitance tomography Measurement 42 368–76
  18. Yang W Q and Peng L 2003 Image reconstruction algorithms for electrical capacitance tomography Meas. Sci. Technol. 14 R1
  19. Mou C, Peng L, Yao D and Xiao D 2005 Image reconstruction using a genetic algorithm for electrical capacitance tomography Tsinghua Sci. Technol. 10 587–92
  20. Gompertz B 1825 On the nature of the function expressive of the law of human mortality, and on a new mode of determining the value of life contingencies Philos. Trans. R. Soc. London 513–83
  21. Marusic M and Bajzer Z 1993 Generalized two-parameter equation of growth J. Math. Anal. Appl. 179 446–62
  22. Turner Jr M E, Bradley Jr E L, Kirk K A and Pruitt K M 1976 A theory of growth Math. Biosci. 29 367–73
  23. Franses P H 1994 Fitting a Gompertz curve J. Oper. Res. Soc. 109–13
  24. Björck A 1996 Numerical methods for least squares problems (Siam)
  25. Demidenko E Z 1989 Optimization and regression Moscow. Publ. House "Nauka". Main Ed. Phys. Math. Lit. 293
  26. Fletcher R 2013 Practical methods of optimization (John Wiley & Sons)
  27. Xie C G, Huang S M, Lenn C P, Stott A L and Beck M S 1994 Experimental evaluation of capacitance tomographic flow imaging systems using physical models Circuits, Devices and Systems, IEE Proceedings- vol 141 (IET) pp 357–68
Index Terms

Computer Science
Information Sciences

Keywords

Electrical Capacitance Tomography Image Reconstruction Linear Back Projection Image Fitting Gompertz function.