CFP last date
20 December 2024
Reseach Article

Modeling Simulation and Fabrication of Fiber Optic Pressure Sensor POBE

by M.L.Dongare, P.B.Buchade, A.D.Shaligram
International Journal of Computer Applications
Foundation of Computer Science (FCS), NY, USA
Volume 1 - Number 14
Year of Publication: 2010
Authors: M.L.Dongare, P.B.Buchade, A.D.Shaligram
10.5120/297-461

M.L.Dongare, P.B.Buchade, A.D.Shaligram . Modeling Simulation and Fabrication of Fiber Optic Pressure Sensor POBE. International Journal of Computer Applications. 1, 14 ( February 2010), 73-75. DOI=10.5120/297-461

@article{ 10.5120/297-461,
author = { M.L.Dongare, P.B.Buchade, A.D.Shaligram },
title = { Modeling Simulation and Fabrication of Fiber Optic Pressure Sensor POBE },
journal = { International Journal of Computer Applications },
issue_date = { February 2010 },
volume = { 1 },
number = { 14 },
month = { February },
year = { 2010 },
issn = { 0975-8887 },
pages = { 73-75 },
numpages = {9},
url = { https://ijcaonline.org/archives/volume1/number14/297-461/ },
doi = { 10.5120/297-461 },
publisher = {Foundation of Computer Science (FCS), NY, USA},
address = {New York, USA}
}
%0 Journal Article
%1 2024-02-06T19:42:14.292960+05:30
%A M.L.Dongare
%A P.B.Buchade
%A A.D.Shaligram
%T Modeling Simulation and Fabrication of Fiber Optic Pressure Sensor POBE
%J International Journal of Computer Applications
%@ 0975-8887
%V 1
%N 14
%P 73-75
%D 2010
%I Foundation of Computer Science (FCS), NY, USA
Abstract

Elastic element mechanical pressure gages consisting diaphragm are basically used for the differential pressure measurement. In FODPS, diaphragm acts as a reflector. A flexible disc of plastic is used as a diaphragm to convert the measuring pressure to the deflection of diaphragm. Concentric corrugations are designed to linearise the deflections according to pressure. Reference and measuring pressures are applied to control and experimental headspaces respectively. As the pressure changes in the experimental head space, the diaphragm is deform and displaces, and distance between fiber tip and plane of diaphragm changes and thus resultant reading is proportional to the differential pressure.

References
  1. Yuan Libo, Ruan Shunling and Pan Jian 1993. ‘Automatic compensation fiber optic differential pressure sensor’, Sensors and Actuators: A, 36 pp. 183-185
  2. O B Wright, D Largeau, 1987. “Fibre-optic differential pressure sensor”, J. Phys. E: Sci. Instrum. 20 pp. 46-51
  3. Berthold J.W. Ghering W.L. and Varshneya, 1987 “Design and characterization of a high temperature fiber optic pressure transducer”, J. light wave technology, 5 pp. 870-876
  4. Arrendale H., 1973 “Precession Pressure Measurement”, Instruments and Control Systems, volume 13,10
  5. Shelke, Kiran Tamadaddi, P.B. Buchade and A.D. Shaligram, 2005 “ Finite Element Modeling and Simulation of Fiber optical based load cell (FOLC) sensor”, Proc. SPIE Vol.5852 pp. 384-389.
Index Terms